FR500A&FR510A Series Vector Control Inverter
- 18 -
Chapter 3 Installation and Wiring
3.1 Installation Environment
1) Ambient temperature in the range of -10
℃~
50
℃
.
2) Drive should be installed on surface of flame retardant object, with adequate surrounding space for
heat dissipation.
3) Installation should be performed where vibration is less than 5.9m/s2 (0.6g).
4) Avoid from moisture and direct sunlight.
5) Protect the cooling fan by avoiding oil, dust and metal particles;
6) Do not expose to an atmosphere with flammable gases, corrosive gases, explosive gases or other
harmful gases.
7) Prevent drilling residues, wire ends and screws falling into drive.
8) Ventilation part of the drive should be installed outside from harsh environment (e.g. Textile facilities
with fiber particles and chemical facilities filled with corrosive gases or Loaded dust cover).
3.2 Installation Direction, Space and Cooling
A fan is integrated in FR500A&FR510A for forced air cooling. FR500A&FR510A has to be installed
vertically for the purpose of good cooling circulation. Sufficient spaces have to be left between
FR500A&FR510A and its peripheral objects. Multi- FR500A&FR510A can be installed in parallel
horizontally e and vertically. See followings for specific space requirement, heat dissipating capacity
and mass airflow.
FR500A&FR510A series inverter installation of the following two:
Wall mounting
Wall-mounted
Remark:
4
~
22kW need to install an optional foot hanging
;
18.5
~
132kW do not need to install an optional foot
hanging.
The wall mount
Through wall-mounted
Fig 3-1 Installation methods