FR200F series Special Purpose Inverter
- 43 -
0Hz
F0
T0
F1
F2
F3
T1
T2
T3=T3.1+T3.2
Output
Frequency
(Hz)
50Hz
F4
F5
T4
Fault
Or
Power
down
T3.1
T3.2
Figure 3-1 Power-off Meomory Function
Thousand’s place: Simple PLC running time
0:s (second
)
1:min
(
minute
)
Set unit of simple PLC running time.
Ten thousand’s place: Set length unit
0: 0.1m
1: 1m
H00.34
Running Mode
0: Linear mode
0
×
1: Gradual mode
2: Length mode
0: Linear mode
Linear mode, when step into a speed, timing starts, and running to the step setting speed by
acce/dece time, when arrive at the speed, inverter continue running as the speed until timing
arrived at setting time.
0Hz
F0
T0
F1
F2
F3
F4
F5
T1
T2
T3 T4 T5 T6
Output
Frequency
(Hz)
F6
F7
T7
F8
T8 T9
F9
F10
T10
F11
T11
F12
T12
F13
T13
F14
T14
F15
T15
50Hz
Acc
Time
Figure 3-2 linear mode running diagram
1: Gradual Mode
Gradual mode, frequency gradually changed from current speed to next setting speed, total