FR150A Series Multifunctional Compact
Inverter
- 41 -
2: Refer to Ai1 channel
3: Refer to AI2 channel
4: Refer to AI3 channel
F14.08
Set count value
1
~
65535
1000
×
F14.09
Designated count value
1
~
65535
1000
×
F14.10
Wakeup frequency
Dormant frequency (F14.12)
~
Fmax
0.00Hz
△
F14.11
Wakeup delay time
0.0
~
6000.0s
0.0s
△
F14.12
Dormant frequency
0.00
~
Wakeup frequency
0.00Hz
△
F14.13
Dormant delay time
0.0
~
6000.0s
0.0s
△
F14.14
Wake up mode selection
0: Frequency
0
×
1: Pressure
F14.15
Dormancy mode selection
0: Frequency
0
×
1: Pressure
F14.16
Voltage feedback source
Unit
’s place: pressure feedback
channel
0: AI1
1: AI2
2: DI7/HI pulse input
00
×
Ten
’s place: pressure dormancy
mode
0:Positive direction, dormancy on
big pressure and wakeup on small
pressure
1:Negative direction, dormancy
on small pressure and wakeup on
big pressure
F14.17
Wake up pressure
0.0%
~
Dormancy pressure
10.0%
△
F14.18
Dormancy pressure
Wake up pressure
~
100.0%
50.0%
△
Group F15: Communication Parameters
F15.00
Baud rate
0: 4800bps
1
×
1: 9600bps
2: 19200bps
3: 38400bps
4: 57600bps
5: 115200bps
F15.01
Data format
No check, data format (1-8-N-2) for
RTU
0
×
1: Even parity check, data format
(1-8-E-1) for RTU
2: Odd Parity check, data format
(1-8-O-1) for RTU
3: No check, data format(1-8-N-1)
for RTU
F15.02
Local address
1
~
247 0: Broadcast address
1
×
F15.03
Communication timeout
0.0
~
60.0s
0.0s
×
F15.04
Response time delay
0
~
200ms
1ms
×
F15.05
Master-slave
Communication Mode
0:The inverter is the slave
0
×
1:The inverter is the master
F15.06
The Master
Communication
Sending Data
0: Set frequency
0
×
1: Current running frequency
F15.07
Information return when
communication error
Range:0
~
1
1
△
F15.08
Group U00.00 output
0: Positive and negative value
0
△