WLA200 Rev140407
6
GENERAL DESCRIPTION
Components
The TankVision consists of the following components:
Display Module
Cab Miniature Display (Optional)
Pressure Sensor
Pressure/Vacuum Relief Vent (Foam Tanks)
MaxVision LED Tank Display (Optional)
Remote Light Driver (Optional)
Buzzer (Optional)
Cables
Display Module
The tank display module is waterproof and has dimensions of 4.4 inches high by
3 inches wide. An output signal from a pressure sensor mounted on the tank is input
to the primary display module. It is processed and the volume of liquid in the tank is
shown on the 9 LED display. Outputs from the primary display module provide tank
volume information to other displays and remote devices.
Non-standard primary displays are used for Foam Fill FFA100 and Auto Tank
ATA400 systems. These require special programs for the correct controlling output
on display connector pin 5.
Cab Miniature Display (Optional)
The cab miniature display has dimensions of 2.75 inches high by 1.5 inches wide.
It provides the option of mounting a remote display in the cab that uses a minimum
of panel space. An output signal from the primary display module is input to the cab
miniature display and the volume of liquid in the tank is shown on the 5-LED display.
Pressure Sensor
The pressure sensor is mounted on a side of the tank near the bottom. It provides a
signal that is proportional to the volume of liquid in the tank to the input of the primary
display module. The electrical connector is waterproof and molded into the pressure
sensor housing.
The standard pressure sensor is used on tanks between 1 and 10 feet in vertical
height. For tanks taller than 10 feet contact FRC for options.