WLA200 Rev140407
25
Power
Datalink
Remote, Cab Miniature, and LED Displays
Remote Display
Module
Standard Harness
Remote Display
Module
Deutsch Plug
DTM06-8S
Remote Display
Connector
Pin Description
1
Power 9-30 VDC
2
Ground
3
N/A
4
N/A
5
Buzzer Ground (150mA)
6
Display Signal Out
7
Datalink (+)
8
Datalink (–)
LED Display Wiring
Wire
Description
Red
Power 9-30 VDC
Black
Ground
Yellow
Datalink (+)
Green
Datalink (–)
Note:
A white wire with a Deutsch contact
on one end (to plug into the standard harness
connector) and a butt connector on the other
(to connect to customer provided wire) is
provided with the Cab Miniature Display.
Wires can be routed
from top, middle, or
bottom feed through.
The datalink requires two terminating resistors.
One TankVision with one or two LED displays: Install resistor at farthest light.
Two TankVision displays: Do not install terminating resistor.
If used with a TurboFoam system: Do not install terminating resistor.
Butt
Connectors
Cab Miniature
Display
LED
Display
Cab Miniature Display
Wiring
Wire
Description
Red
Power 9-30 VDC
Black
Ground
White
Display Signal
Figure 9. Remote, Cab Miniature, and LED Display Wiring
White Wire
TankVision
Pin
Yellow 7
Green
8
Power