background image

XIFOS 33

OPERATING 

INSTRUCTIONS

WITH INTEGRATED REMOTE MONITOR

Summary of Contents for XIFOS 33

Page 1: ...XIFOS 33 OPERATING INSTRUCTIONS WITH INTEGRATED REMOTE MONITOR...

Page 2: ......

Page 3: ...Wiring Examples 20 12 Specification and Dimensions 24 13 Certification and CE Declaration of Conformity 25 14 Spare Parts and Accessories 26 Fraser static control equipment has been designed to give...

Page 4: ...lisation of electrostatically charged surfaces Powered by 24 V DC it features integrated high voltage supplies meaning that no high voltage cabling is required 1 Introduction Mounting onto the machine...

Page 5: ...e damage contact the Factory or one of our Distributors before carrying out any installation Check that the parts which have been delivered are the same as you have ordered Loose Parts Bars up to 1 00...

Page 6: ...pins of the bar are necessarily sharp The emitter pins are a Class 2 mechanical energy source as defined in EN 62368 1 2014 Contact with them may be painful but will not cause an injury requiring emer...

Page 7: ...ine the best position Important Except on a winding reel of material see the examples on the following page the material to be neutralised must be in free air not touching another surface as it passes...

Page 8: ...he reel which is shown by the following diagrams The principle is to neutralise the film AFTER it leaves the final roller and as it joins the reel If there is a lay on or contact roller C the best pos...

Page 9: ...t is better to place the bar facing down since the face of the bar will not be covered by the dust This is not a problem It is possible to position the bar at other positions such as B and still achie...

Page 10: ...or the mounting bracket When mounting to the machine or on a bracket make sure no metal extends beyond the slot in the bar See the diagram below Note Long bars need careful handling during installati...

Page 11: ...or on the endcap of the bar If using the Fraser Anti Static external Power Supply Unit Part No NEOS PSU connect the M12 cable from the Power Supply Unit to the bar and ensure that the supplementary gr...

Page 12: ...ther cables can have different colour schemes Pin Colour Function 1 Brown 24 V 2 White OK 3 Blue 0 V and Earth 4 Black Status 5 Grey or Green Yellow Disable Pin 3 Pin 2 Pin 1 Pin 5 Pin 4 5 1 M12 Pin A...

Page 13: ...ction is made externally Warning If the 0 V output of the DC power supply is not grounded there is a risk that the operator can receive an electric shock from the M12 connector on the bar Caution If t...

Page 14: ...he bar is not powered Inactive All flashing red Standby mode Inactive All solid red There is a fault with the bar Inactive All flashing green red Clean Me The bar needs attention Active All flashing g...

Page 15: ...e Distance Control alters the frequency of the duty cycle High frequency is best for short range Low frequency is best for long range Control Position Neutralisation Distance Frequency 1 250 mm 500 mm...

Page 16: ...ycle and frequency of the ion emission to suit the application The Intelligence setting can double the neutralisation power of a XIFOS 33 bar in Manual mode XIFOS 33 Intelligence monitors the charge i...

Page 17: ...IFOS 33 bar these could interfere with the sensing giving it misleading information See Installation in Section 4 3 Intermittent Static Charge For example if the target is not continuously present the...

Page 18: ...sation effectiveness and result in unsatisfactory static neutralisation performance The frequency of cleaning will depend on the process and the environment in which the bar is installed The bar shoul...

Page 19: ...tallation of the bar Move the bar further from earthed metal objects Check the bar for damage Internal fault Contact your supplier Alternate flashing red green LEDs Emitters need cleaning Turn off the...

Page 20: ...r status and a DISABLE input to allow the HV supplies to be externally disabled when not required Standby mode For example the bar can be linked into the safety interlock system of the machine to ensu...

Page 21: ...n will thus internally connect both outputs to 20 V Signalling becomes valid 5 seconds after power is applied Caution Voltage applied to the outputs must not exceed 28 V DC and must be of the correct...

Page 22: ...ut can be achieved by direct connection External relay An external relay can be connected for additional control feedback applications Coil rating 24 V 1 2 W max STATUS OK BLACK WIRE WHITE WIRE MAX 50...

Page 23: ...ply is bonded to Ground With this optional supply an interface cable is required to access the remote monitor feature 11 3 Remote DISABLE input The XIFOS 33 bar features a remote DISABLE input signal...

Page 24: ...outputs OK and Status Signalling levels 0 V 24 V output Output current Sourcing 24 V 50 mA Sinking 0 V 50 mA Limited to 50 mA max PLC Compatibility Compatible with IEC 61131 2 Type 1 2 and 3 PLC input...

Page 25: ...MCD 2014 30 EU Emissions EN 61000 6 3 2007 Immunity EN 61000 6 2 2005 We declare that this equipment conforms to the following EU Directives Low Voltage Directive 2014 35 EU EMC Directive 2014 30 EU a...

Page 26: ...ds Straight socket 81194 7 5 m cable M12 female bare ends Straight socket 81195 10 m cable M12 female bare ends Straight socket 81196 3 m cable M12 female bare ends 90 socket 81199 5 m cable M12 femal...

Page 27: ...C 24 V DC output Fitted with 1 5 m of cable NEOS PSU XIFOS 33 T fixing 40 mm including flanged nut 36321 Replacement Emitter 34201 Replacement Emitter Key 342018 Fraser Ioniser Cleaning Kit 500 ml of...

Page 28: ...DN UK T 44 0 1398 331114 F 44 0 1398 331411 E sales fraser antistatic co uk W www fraser antistatic com XIFOS 33 OI Iss 3 EN For more information about static and to view the full range of our product...

Reviews: