BEFORE YOU START

BEFORE INSTALLING PUMP, BE SURE TO READ 
THIS OWNER’S MANUAL CAREFULLY. 
REFER TO PRODUCT DATA PLATE(S) FOR 
ADDITIONAL OPERATING INSTRUCTIONS AND 
SPECIFICATIONS.

Keep work area clean, well-lit and uncluttered.
Keep safety labels clean and in good condition.
Wear safety glasses while installing or performing 
maintenance on pump.
Adhere to the guidelines of the National Electric Code 
(NEC) or Canadian Electric Code (CEC), and any other 
state and local codes for ALL electrical installations.  
Check with the appropriate agencies or contact a 
licensed electrician.
Most water system problems result from improper 
installation. It is suggested that you read this manual 
carefully before installing your pump.
The “TROUBLESHOOTING SECTION” will assist you in 
locating and eliminating the cause of any trouble you may 
encounter after installation. Check and make available all 
the tools you will need to install your pump. Required 
tooling may include wrenches, pipe sealant, pipe fittings 
and nipples, screwdriver, etc. Be sure to have available 
proper and adequate wiring material to complete the 
installation correctly.

READ AND FOLLOW SAFETY INSTRUCTIONS

This is the safety alert symbol.  When you see this 
symbol on your pump or in this manual, look for one 

of the following signal words and be alert to the potential 
for personal injury:

Hazardous voltage.
Can shock, burn, or
cause death.

Ground pump before
connecting to power
supply. Disconnect
power before working
on pump, motor 
or tank.

WA R N I N G

Hazardous voltage.
Can shock, burn, or
cause death.

Ground pump before
connecting to power
supply. Disconnect
power before working
on pump, motor 
or tank.

WA R N I N G

CAUTION

CAUTION

WARNING

OWNER'S MANUAL

CONVERTIBLE VERSAJET SERIES

SHALLOW WELL JET PUMP

D A N G E R

 warns about hazards that 

will cause 

serious personal injury, death or major property damage 
if ignored.

WARNING

 warns about hazards that 

can cause 

serious personal injury, death or major property damage 
if ignored.

CAUTION

 warns about hazards that

 will or can cause 

minor personal injury or major property damage if 
ignored.
NOTICE indicates special instructions, which are 
important but not related to hazards.
Carefully read and follow all safety instructions in 
this manual and on pump.
Keep safety labels in good condition. 
Replace missing or damaged safety labels.

HAZARDOUS PRESSURE: Do not run 

pump against closed discharge. Release all system 
pressure before working on any component.

Do not run pump dry. Fill pump with water 

before starting or pump will be damaged. 
The motor on this pump is guaranteed by the 
manufacturer and in event of failure it must be returned to 
an authorized service station for repairs. Motor warranty 
is void if repairs aren’t made by an authorized             
repair station.

NOTICE: If necessary, adjust pressure switch 
cut- out setting so that pump will not run 

continuously. Continuous operation at shut-off pressure 
will damage pump and may damage other system 
components.

ELECTRICAL SAFETY

CAUTION

 Make sure all ELECTRICAL POWER IS 

OFF before connecting any electrical wires.

CLICK ANYWHERE on THIS PAGE to RETURN to WATER & WELL PUMP MANUALS & INFORMATION at
InspectApedia.com

Summary of Contents for VersaJet Series

Page 1: ...otor or tank WARNING Hazardous voltage Can shock burn or cause death Ground pump before connecting to power supply Disconnect power before working on pump motor or tank WARNING CAUTION CAUTION WARNING...

Page 2: ...to make sure there is no damage or broken parts that may have occurred in shipping If damage is evident report this immediately to your shipping carrier and dealer The shipping carrier assumes full r...

Page 3: ...y have to be increased in diameter to reduce pressure loss The pressure loss in a system increases 1 As the flow rate increases 2 As the piping size decreases Consult included friction loss tables App...

Page 4: ...pumping of a low yield well Lower the injector assembly into the well It should be set at least 3 below the lowest dynamic water level if you are not using a tail pipe below the injector The foot val...

Page 5: ...e that has an alternate NPT pressure switch connection This alternate pressure switch connection allows the switch to read the pressure on the outbound side of the valve rather than inside the pump ca...

Page 6: ...mply with National Electric Code NEC or Canadian Electric Code CEC and all applicable local codes All dual voltage units come factory preset for 230 volts Figure 6 Disconnect power at electrical panel...

Page 7: ...filling the pump case completely full of water as damage may occur to the seal and other internal components if run dry PRESSURE SWITCH ADJUSTMENT EXAMPLE ASSUMES PRESSURE SWITCH IS INITIALLY SET WITH...

Page 8: ...g bolted to front of the pump If you need to service the impeller motor or seal use the following procedure going as far as needed to correct the problem 1 Disconnect the power to the unit 2 Disconnec...

Page 9: ...NT in this manual Increase size or clean out suction piping to pump Clear nozzle or impeller of clogging debris See PUMP DISASSEMBLY in manual Convert a shallow well application into a deep well arran...

Page 10: ...4 305374907 305374905 2 Studs B 305465901 3 Bracket 4 O Ring F 305465902 5 Fasteners C 305465903 6 Pressure Switch D 305465904 7 Pressure Hose Fitting 8 Pressure Hose Tubing 9 Plugs E 305465905 10 Mec...

Page 11: ...applicable codes ordinances and good trade practices 3 Product was not installed by a Franklin Certified Contractor or Franklin Key Dealer or 4 Product was damaged as a result of negligence abuse acc...

Page 12: ...106580101 Rev 2 07 13 9255 Coverdale Road Fort Wayne IN 46809 Tel 260 824 2900 Fax 260 824 2909 www franklinwater com...