2

TABLE 1

 

CAUTION 

Undersize wire between the motor and the power source will adversely 
limit the starting  and load carrying abilities of the motor.  Minimum wire 
sizes for the motor branch circuits are recommended in table 1.

TABLE 2–  FRICTION LOSS CHART FOR PLASTIC PIPE:

For galvanized pipe, double the fi gures.
Loss of head in feet, due to friction per 100 feet of pipe.

Loss of head in meters, due to friction per 100 meters of pipe.

1-1/4" Suction
Hose

Foot Valve

Priming Plug

Street Tee (not 
included)

Garden Hose Adaptor
(included)

To Sprinkler System

Garden Hose

Weather Proof Enclosure

To 115v
Grounded Outlet

Base

To Sprinkler
 System

Handle

To 115v
Grounded
 Outlet

Base

INSTALLATION

ALTERNATE INSTALLATION AS A BOOSTER PUMP

Garden Hose

Street Tee
 (not included)

1-1/4"
Suction Hose

Garden Hose Adaptor (included)

Fig. 1

Nominal

Pipe Size

U.S. 

GPM

3/4"

1"

1"-1/4''

1-1/2''

2''

4

3.75

1.15

0.30

0.14

5

5.66

1.75

0.46

0.22

6

7.95

2.45

0.65

0.31

7

10.60

3.25

0.86

0.41

8

13.50

4.16

1.10

0.52

9

16.80

5.17

1.35

0.65

10

20.40

6.31

1.67

0.79

0.23

11

24.40

7.58

1.98

0.95

0.27

12

28.60

8.85

2.33

1.10

0.32

14

38.00

11.80

3.10

1.46

0.43

16

48.60

15.10

3.96

1.87

0.55

18

60.50

18.70

4.93

2.33

0.69

20

73.50

22.80

6.00

2.83

0.84

Nominal

Pipe Size

L/Min.

20mm

25mm

32mm

40mm

50mm

15

3.7

1.15

0.30

0.13

 20

5.3

1.64

0.43

0.19

 25

7.1

2.18

0.56

0.27

 30

13.5

4.13

1.08

0.49

35

16.3

5.00

1.31

0.61

40

23.5

7.30

1.90

0.88

0.25

45

28.3

8.74

2.31

1.07

0.29

50

34.2

10.60

2.79

1.32

0.38

55

40.7

12.60

3.32

1.56

0.46

60

48.1

14.90

3.92

1.85

0.54

65

55.7

17.30

4.45

2.15

0.63

70

63.8

19.70

5.20

2.46

0.73

75

72.2

22.40

5.89

2.78

0.83

Reccommended Wire Gauge For Electrical Cord Length

HP

Volts

0-25 ft.

50ft.

100ft.

150ft.

200ft.

1/2

115

14

12

10

8

6

Summary of Contents for RJSE

Page 1: ...inklers and a multi tude of other general purpose applications This pump is suitable for installations where the vertical distance from the pump to the water level does not exceed 25 ft 7 6m including...

Page 2: ...uded 1 1 4 Suction Hose Garden Hose Adaptor included Fig 1 Nominal Pipe Size U S GPM 3 4 1 1 1 4 1 1 2 2 4 3 75 1 15 0 30 0 14 5 5 66 1 75 0 46 0 22 6 7 95 2 45 0 65 0 31 7 10 60 3 25 0 86 0 41 8 13 5...

Page 3: ...ect into the impeller vane 7 Slip the rotating seal 7 off the shaft and remove the seal plate 8 8 Remove the ceramic seal seat 9 from the seal plate Reassembly 1 Clean all the parts thoroughly before...

Page 4: ...ructions Warranty will be VOID if any of the following conditions are found 1 Product is used for purposes other than those for which it was designed and manufactured 2 Product not installed in accord...

Page 5: ...s d une installation d port e il faut aussi tenir compte des pertes par frottement dans la conduite d aspiration Consultez le Tableau 2 Pertes par frottement Moins aux hautes altitudes AVERTISSEMENT R...

Page 6: ...e refoule ment INSTALLATION Clapet de pied Tuyau flexible d aspiration de 1 1 4 po T m le femelle non compris Adapteur de tuyau d arrosage compris Bouchon d amor age Tuyau flexible d arrosage Enceinte...

Page 7: ...l me on a pr vu un bouchon de 1 4 po filetage NPT qui permet de nettoyer l injecteur venturi Ce bou chon se trouve directement en dessous de l orifice d aspiration sur le devant du carter IMPORTANT Av...

Page 8: ...pour des applications autres que celles pour lesquelles il a t con u et fabriqu 2 Le produit n est pas install dans le respect des codes et r glements applicables et selon les bonnes pratiques accept...

Page 9: ...el riesgo de una descarga el ctrica aseg rese que est conectada solamente a un tomacorrientes adecuadamente conectado a tierra y del tipo con conector a tierra Se recomienda se use un circuito protegi...

Page 10: ...como se muestra en la figura 1 El tama o requerido de la l nea de servicio depende completamente de la cantidad de agua que se necesita y del largo de la tuber a La tuber a que se elija debe ser sufic...

Page 11: ...mas de obstrucci n se ha proporcionado un tap n de 1 NPTpara tener acceso a limpiar la boquilla venturi Este tap n est ubicado directamente debajo de la apertura de succi n en la parte frontal del cu...

Page 12: ...hallan cualesquiera de las siguientes condiciones 1 El producto se utiliza para prop sitos distintos a aquellos para los cuales fue dise ado y fabricado 2 El producto no fue instalado de conformidad...

Reviews: