background image

BEFORE OPERATING OR 
INSTALLING THIS PUMP, READ 
THIS MANUAL AND FOLLOW 
ALL SAFETY RULES AND 
OPERATING INSTRUCTIONS. 

SAFETY WARNINGS

APPLICATION

INSTALLATION

 CAUTION

 

DO NOT OPERATE THIS PUMP DRY!

• 

Review instructions before operating.

• 

Wear ear protection to reduce objectionable noise.

 WARNING

• 

Review chemical manufacturer's safety precautions before 
handling.

• 

Make sure all connections are tight.

• 

Do not breathe or ingest fumes or chemicals.

• 

Never use with fl ammable fl uids.

• 

Turn off engine before servicing.

• 

If fuel is spilled, avoid creating any source of ignition until 
the fuel vapors have been cleaned up and removed.

CAREFULLY READ THESE SAFETY 
MESSAGES IN THIS MANUAL AND ON PUMP.

 SAFETY

FBSGF Series Self-Priming 
Centrifugal Pumps

OWNER'S MANUAL

Use these pumps on water or liquid fertilizer, where the vertical 
suction from the liquid level is 25 ft. (8m) or less.
The elevation above sea level, and friction losses, must be taken 
into consideration. 

NOTE:

 Do not operate this pump dry for more than two minutes. 

This pump has been tested and operated under actual working 
conditions. Engine, pump and all accessories were found sat-
isfactory.  If pumping unit is not performing as specifi ed, check 
installation and Troubleshooting Guide carefully. 

Refer to Fig. 1.

a)

 

LOCATION:

 For permanent installation, put the pump in a 

clean, dry and ventilated place.

 

Keep the suction line as short as possible. This keeps pump-
ing fl ow at its highest.

b)

 

MOUNTING:

 Mount the pump on a rigid foundation to elimi-

nate creeping due to vibration.

c)

 

SUCTION LINE:

 Use a suction line the same size as the 

suction on the pump. If the suction pipe is long, increase it by 
one size to improve fl ow. Slope the suction line upwards to 
the pump to avoid air pockets in the line and hard priming.

d)

 

SUCTION PIPE:

 Use thread compound on all pipe joints. 

Connections must be tight. Clean, uncorroded pipe is recom-
mended.

e)

 

SUCTION HOSE:

 If the suction line runs basically vertically, 

use an elbow on the hose to prevent kinking. Use double 
clamps on all hose joints. Connections must be tight.

NOTE: 

  If you use the pump for dewatering, attach a foot 

valve to the suction line.

NOTE:

   The main cause of pumping problems is a leak in 

the suction line. Even a tiny leak reduces priming 
and pumping greatly.

Summary of Contents for FBSGF Series

Page 1: ...een tested and operated under actual working conditions Engine pump and all accessories were found sat isfactory If pumping unit is not performing as specified check installation and Troubleshooting G...

Page 2: ...has drained run the pump for a few seconds to get the last liquid out of the impeller Make sure the suction and discharge lines are free of liquid Refer to Fig 2 DISASSEMBLY 1 Drain the pump see Drai...

Page 3: ...s c Piping hosing used is smaller than the thread sizes on the pump a Clean the lines and fittings b Check to see that the valves are in good working order c Increase size of hose pipe to reduce fric...

Page 4: ...er or 4 Product was damaged as a result of negligence abuse accident misapplication tampering alteration improper installation operation maintenance or storage nor to an excess of recommended maximums...

Page 5: ...et a r La longueur de la conduite d aspiration doit tre r duite au minimum afin de permettre un d bit maximum Garder le d bit de pompage le plus lev b MONTAGE Fixerlapompesurunebaserigidepour liminer...

Page 6: ...de turbine 2 la desserrer en frappant sur celle ci avec un maillet de caoutchouc Faire tourner ensuite la roue de turbine dans le sens contraire des aiguilles d une montre 5 Pour enlever le joint 8 l...

Page 7: ...i des orifices de la pompe a Nettoyer les conduites et les raccords b V rifier si les soupapes sont en bon tat de c Augmenter le diam tre des tuyaux ou des boyaux afin de r duire les pertes dues au fr...

Page 8: ...tion de proc dures d installation d op ration d entretien ou d entreposage non conformes ou pour cause d utilisation exc dant les maximums recommand s tel que stipul dans les instructions concernant l...

Page 9: ...posible para mantener el flujo de bombeo al m ximo b INSTALACI N Instale la bomba sobre unos cimientos r gidos para eliminar su movimiento por la vibraci n c L NEA DE SUCCI N Use una l nea de succi n...

Page 10: ...quido al superficie exterior del cubo de goma 4 sobre el asiento inm vil 9 Inserte el asiento inm vil del sello dentro del adaptador Aseg rese que el lado liso del asiento de cer mica est hacia el fr...

Page 11: ...bierta c Las tuber as mangueras usadas son m s peque as que el tama o de rosca de la bomba a Limpie las l neas y los acoplamientos b Aseg rese que las v lvulas est n funcionando bien c Aumente el tama...

Page 12: ...ado por negligencia abuso accidente aplicaci n indebida modificaci n alteraci n instalaci n inadecuada operaci n mantenimiento o almacenamiento o como resultado del abuso de los l mites recomendados...

Reviews: