NOTE:
Ensure that the system is properly grounded all the way to the service entrance
panel. Improper grounding may result in the loss of voltage surge protection and
interference filtering.
1. Verify that the power has been shut off at the main breaker.
2. Verify that the dedicated branch circuit for the SubDrive/MonoDrive is equipped with a
properly-sized circuit breaker. (See Table 1, pg. 15 for minimum breaker size.)
3. Use appropriate strain relief or conduit connectors. See below for conduit hole and
knockout sizes.
4. Remove the SubDrive/MonoDrive lid.
5. Feed the motor leads through the
opening on the bottom right side of the
unit and connect them to the terminal
block positions marked (Green
Ground Wire), Red, Yellow and Black.
Tighten terminals to 15 in-lbs (1.7 Nm).
s
WARNING
!
Serious or fatal electrical shock may result from failure to connect the motor, the SubDrive
MonoDrive, metal plumbing, and all other metal near the motor or cable to the power supply
ground terminal using wire no smaller than motor cable wires. To reduce risk of electrical
shock, disconnect power before working on or around the water system. Do not use motor in
swimming areas.
28,6 HOLE
[1.13]
34.9 KNOCKOUT
[1.37]
[0.5]
HOLE
12,7
[1.13]
28.6 KNOCKOUT
]
0.88
[
HOLE
22,2
22,2
KNOCKOUT
[0.88]
47,7
[1.88]
97,7
[3.85]
97,7
[3.85]
33,6
[1.32]
40,3
[1.59]
82,3
[3.24]
110.7 [4.36]
MD/MDXT/SD15
SD20/SD30
119.1 [4.69]
SD50
198.3 [7.81]
MD/MDXT/SD15/SD20/SD30
205.3 [8.08]
SD50
Drive Wiring
Summary of Contents for 5870205003C
Page 1: ...Owner s Manual SubDrive15 20 30 50 MonoDrive MonoDriveXT Connect NEMA 3R ...
Page 45: ...NOTES ...
Page 46: ...SubDrive15 20 30 50 MonoDrive MonoDriveXT Connect NEMA 3R Manual del propietario ...
Page 90: ...NOTAS ...
Page 91: ...Manuel du propriétaire SubDrive15 20 30 50 MonoDrive MonoDriveXT Connect NEMA 3R ...
Page 135: ...REMARQUES ...