0
50
40
30
20
10
45
60
55
35
25
15
5
0
20
40
60
80
100
120
140
160
180
200
220
240
260
280
300
Airflow
P1
P2
[Pa]
P3
P4
[m
3
]
[Pa]
[m
3
]
Einstellw
erte /
Calib
ration
/ Cal
ibrazi
one
Hold
Max
/Min
Vol
AUTO
AUTO
Links
versio
n(A)
Left u
nit
unitá
sinist
ra
Versio
n gau
che
Recht
svers
ion(B
)
Right
unit
unitá
destra
Versio
n droi
te
B
AUTO
A
AUTO
Airflow
AUTO
AUTO
Links
versio
n(A)
Left u
nit
unitá
sinist
ra
Versio
n gau
che
cockpit pro
Settings
0
50
40
30
20
10
45
60
55
35
25
15
5
0
20
40
60
80
100
120
140
160
180
200
220
240
260
280
300
Airflow
P1
P2
[Pa]
P3
P4
[m
3
]
[Pa]
[m
3
]
Einstel
lwerte
/ Cal
ibrati
on / Ca
libraz
ione
Hold
Max/Min
Vol
Installation and operating instructions profi-air 250/360 flex
45
3.19 Optional replacement filter set G4 / F7 (ISO Coarse 75 % / ePM1 55 %)
The profi-air flex ventilation unit is delivered with one supply air filter and one extract
air filter ISO Coarse 75 % (G4) as a standard feature. You can optionally replace
the supply air filter with an ePM1 55 % (F7) filter. The ePM1 55 % (F7) filter is best
suited for people suffering from allergies.
If retrofit replacement of the G4 filter with the F7 filter takes place,
control of supply air fans has to be adjusted due to higher pres-
sure loss. Please refer to Section 9.3 for more information.
3.18 cockpit pro connection cable
The profi-air cockpit pro connection cable establishes a connection between the
ventilation unit and the commissioning software. You will need this if you want to
perform commissioning using this software. The connection cable features the
following plug types: USB type A / USB type B.
To establish a connection between the profi-air cockpit pro and the ventilation unit,
the following steps are required (be sure to observe the correct order):
n
The ventilation unit / laptop are in operation.
n
Connect the USB cable to the ventilation unit.
n
Connect the USB cable to the laptop.
n
Start the profi-air cockpit pro software.
n
It may be required to press the “Reload“ button.
If the ventilation unit is not displayed or the ventilation unit is rec-
ognised as a USB drive (function for software update). Disconnect
all connections, restart the ventilation unit and repeat the steps
described above.
If the ventilation unit is displayed as a USB drive, do not delete
any files of this drive.
Summary of Contents for profi-air 250/360 flex
Page 104: ...Installation and operating instructions profi air 250 360 flex 104 Notes...
Page 105: ...Installation and operating instructions profi air 250 360 flex 105 Notes...
Page 106: ...Installation and operating instructions profi air 250 360 flex 106 Notes...
Page 107: ...Installation and operating instructions profi air 250 360 flex 107 Notes...