Installation and operating instructions profi-air 250/360 flex
101
Manufacturer
FRÄNKISCHE Rohrwerke Gebr. Kirchner GmbH & Co. KG
Hellinger Straße 1, 97486 Königsberg/Germany
Type of product
profi-air 360 flex
Catalogue number
78304736
Additional equipment
min. 2 sensors 78300841
Specific energy consumption
SEC
cold
–81.2
[kWh/(m² a)]
average
–42.5
warm
–17.7
Energy efficiency grade
A+
Type
RVU / BVU
Type of drive
VSD
Type of heat recovery
recuperation
Thermal efficiency
η
t
86
[%]
Highest airflow rate
360
[m³/h]
Electric power input
230
[W]
Sound power level
L
WA
50
[dB[A]]
Reference airflow rate
0.07
252
[m³/s]
[m³/h]
Reference pressure difference
50
[Pa]
Specific power input
SPI
0.24
[W/(m³/h)]
Control typology
peripheral demand control
Control factor
0.65
Highest internal air leakage rate
< 2
[%]
Highest external air leakage rate
< 2
[%]
Location and description of filter warning indicator
fault report indicator on the control panel (visual)
Website
www.fraenkische.com
Annual energy consumption
AEC
cold
7.09
[kWh/(m² a)]
average
1.72
warm
1.27
Annual heating energy savings
AHS
cold
90.2
[kWh/(m² a)]
average
46.1
warm
20.8
10.4 profi-air 360 flex ventilation unit with external sensors
Summary of Contents for profi-air 250/360 flex
Page 104: ...Installation and operating instructions profi air 250 360 flex 104 Notes...
Page 105: ...Installation and operating instructions profi air 250 360 flex 105 Notes...
Page 106: ...Installation and operating instructions profi air 250 360 flex 106 Notes...
Page 107: ...Installation and operating instructions profi air 250 360 flex 107 Notes...