![background image](http://html1.mh-extra.com/html/franke/bbr-series/bbr-series_installation-and-operating-manual_2327826015.webp)
BBR Operating Manual
Page 15
§
Clean, sanitize and dry that shelf component and any others soiled
by the leak.
§
At end of day, initiate full (Monthly) case cleaning, per instructions
in Section 6, beginning page 17.
7 Preventive Maintenance
1 Empty & Clean Display Case (Monthly)
Once a month the display case should be shut down, emptied and
given a thorough cleaning, as follows:
§
Turn OFF power at switch.
§
Unplug unit from 120-volt power outlet.
§
Open doors, lock in OPEN position and remove all product from
shelves. Any perishable product (milk) should be put into
refrigerated storage elsewhere.
§
Remove all wire form shelf components including bottom shelves
and one piece middle shelf.
WARNING!
Verify refrigerator is disconnected from the power source
before attempting any preventive maintenance. Failure to disconnect the
electric power could result in electric shock, burns, injuries or death.
CAUTION!
The fins on a condenser coil are very sharp, and some
refrigeration lines can be very hot, resulting in possible cuts and/or
burns. Avoid physical contact with the fins on the condenser coil or any
related refrigeration lines. Gloves are recommended when accessing the
internal components of any refrigerated equipment.
CAUTION!
The compressor and condenser is located in a service
compartment above the display case, which is seven feet above floor
level. Any individual performing maintenance should use a ladder or safe,
stable work platform to access and clean the service compartment. Do
not stand on equipment positioned below the BBR. Use caution to avoid
falls and potential injuries when performing preventive maintenance.
Note! Use only McDonald
s approved cleaning and sanitizing
agents, according to instructions.