ZMI
_001_
2030
0366
54-A
C
EX90
05_#
SEN_#
AQU_V
1
.f
m
- 36 -
39. Starting Hygiene Purge
Hygiene Purge can be started manually if required.
Select the following menu items to go to the destination display:
39.1
Select “Hygiene Flush” with “
” buttons.
39.2
Press the “
OK
” button.
39.3
Set to “
START
” with “
” buttons.
39.4
Confirm with “
OK
” button.
39.5
Press the
button.
• Hygiene Flush starts.
☞
Only the selected action is executed.
☞
Hygiene Flush can be ended ahead of time.
39.6
Select “Hygiene Flush” with “
” buttons.
39.7
Press the “
OK
” button.
39.8
Set to “
STOP
” with “
” buttons.
39.9
Confirm with “
OK
” button.
39.10
Press the
button.
• Hygiene Flush is ended.
14-Jan-2018 16:03
0×-Tap
×××
Sensor Functions
0X Tap Functions
Cleaning
Hygiene Flush
Basin Filling
Actuator 1
Actuator 2
START
START
START
START
START
START
TD