ZMI
_001_
2030
0366
54-A
C
EX90
05_#
SEN_#
AQU_V
1
.f
m
- 22 -
24. Activating Power Function
☞
This function generates higher energy consumption at the tap.
When Power Function is activated, the detection area is scanned by the tap sensor
approx. 10 times more frequently.
Select the following menu items to go to the destination display:
24.1
Select “Power Function” with “
” buttons.
24.2
Press the “
OK
” button.
24.3
Set “Power Function” to “
ON
” with “
” buttons.
24.4
Confirm with “
OK
” button.
24.5
Press the
button.
• The parameter change is sent to the tap.
Sensor Settings
0X Tap Menu
0×-Tap ×××
14-Jan-2018 16:03
0×-Tap
×××
TD Safety Period
TD Water Saving F
Mode of Operation
Power Function
Basin Filling
0m
OFF
ON
OFF
OFF
TD Delay Time
10s
TD Impact Time
5m
TD Cooling Time
2m