background image

ZMI

_001_

2030

0366

54-A

C

EX90

05_#

SEN_#

AQU_V

1

.f

m / 02/

03

/20

1

8

Installation and operating instructions

Reader 

EA-Nr.:

7612982239441

FAR-Best.-Nr.: 2030036654

ACEX9005

DE

EN

FR

ES

IT

NL

PL

SV

CS

FI

RU

Summary of Contents for 2030036654

Page 1: ...ZMI_001_2030036654 ACEX9005_ SEN_ AQU_V1 fm 02 03 2018 Installation and operating instructions Reader EA Nr 7612982239441 FAR Best Nr 2030036654 ACEX9005 DE EN FR ES IT NL PL SV CS FI RU...

Page 2: ...ettings Memory 15 17 Displaying Stored Settings 15 18 Sending Settings 16 19 Deleting Stored Settings 17 Basic settings 20 Setting Flow Time 18 21 Setting Run On Time 19 22 Setting Range 20 23 Setting...

Page 3: ...ygiene Flow Time 35 39 Starting Hygiene Purge 36 Thermal Disinfection 40 Requests for thermal disinfection 37 41 Setting TD Delay Time 38 42 Setting TD Impact Time 39 43 Setting TD Cooling Time 40 44...

Page 4: ...ce with the General Terms and Conditions of Business and Supply Caution The statistical data is provided to show trends in user behaviour and frequency of use The hygiene purge data is provided to ass...

Page 5: ...5 ZMI_001_2030036654 ACEX9005_ SEN_ AQU_V1 fm 5 Scope of delivery 6 Dimensions...

Page 6: ...struction No Designation 1 Opto electronic interface infrared 2 Display 2 1 Date Time 2 2 Battery status 3 On Off button Standby 4 Receive button 5 On Off switch 6 Navigation buttons 7 OK button 8 Sen...

Page 7: ...to make settings Important The sensor must be activated before using the Reader move your hand towards the sensor The Reader is controlled via the following buttons The OK button opens a menu item and...

Page 8: ...Shower Timer 13 Shower Timer body 0X Tap Functions 1X Shower Functions Menu with START STOP function Menu with START STOP function Sensor statistics Readout statistics Display statistics List of stor...

Page 9: ...x 0 5 A 5 V DC Charging with the Reader switched on 10 1 Connect the Reader to a PC The following icon appears in the top right hand corner of the Reader display Charging with the Reader switched off...

Page 10: ...the display in all menu levels Select the following menu items to go to the destination display 11 1 Select parameters with buttons 11 2 Set parameters with buttons 11 3 Confirm with OK button The se...

Page 11: ...lay switches off Key Beep Each keypress generates a noise when Key Beep is activated The other parameters cannot be changed Select the following menu items to go to the destination display 12 1 Select...

Page 12: ...Important The Reader must be set to the Mass Storage Mode before it is recognised by the PC as an external drive Select the following menu items to go to the destination display 13 1 Insert USB cable...

Page 13: ...a PC see Chapter 13 14 2 Drop the new firmware file in the main folder of the mass storage device 14 3 Select the following menu items to go to the destination display 14 4 Select the new FirmwareUpd...

Page 14: ...ed Select the following menu items to go to the destination display 15 1 Press the button Parameters are read out If a connection could not be made the following display appears 15 2 Confirm with Yes...

Page 15: ...go to the destination display 17 1 Select the respective setting with the buttons 17 2 Confirm with OK button Settings are imported to the Reader and displayed Sensor Settings 0X Tap Menu 0 Washbasin...

Page 16: ...apter 23 18 2 Press the button Sending the complete settings 18 3 Select the following menu items to go to the destination display 18 4 Navigate to Send Settings with the buttons 18 5 Confirm with OK...

Page 17: ...the buttons 19 3 Press and hold down the OK button until the following display appears 19 4 Confirm with Yes The setting is deleted Deleting settings via the USB Mass Storage Mode 19 5 Connect the Re...

Page 18: ...menu items to go to the destination display 20 1 Select Flow Time with buttons 20 2 Press the OK button 20 3 Select Flow Time with buttons 1 255s 20 4 Confirm with OK button 20 5 Press the button The...

Page 19: ...owing menu items to go to the destination display 21 1 Select Run On Time with buttons 21 2 Press the OK button 21 3 Select Run On Time with buttons 1 255s 21 4 Confirm with OK button 21 5 Press the b...

Page 20: ...the F5 tap series Select the following menu items to go to the destination display 22 1 Select Range with buttons 22 2 Press the OK button 22 3 Select Range with buttons 0 100 22 4 Confirm with OK but...

Page 21: ...wing menu items to go to the destination display 23 1 Select Mode of Operation with buttons 23 2 Press the OK button 23 3 Select Mode of Operation with buttons ON OFF STB 23 4 Confirm with OK button 2...

Page 22: ...llowing menu items to go to the destination display 24 1 Select Power Function with buttons 24 2 Press the OK button 24 3 Set Power Function to ON with buttons 24 4 Confirm with OK button 24 5 Press t...

Page 23: ...lowing menu items to go to the destination display 25 1 Select Power On Rinse with buttons 25 2 Press the OK button 25 3 Set Power On Rinse to ON with buttons 25 4 Confirm with OK button 25 5 Press th...

Page 24: ...ion can be started see Chapter 33 Select the following menu item to go to the destination display 26 1 Select TouchCODE with buttons 26 2 Press the OK button 26 3 Set TouchCODE to ON with buttons 26 4...

Page 25: ...nation display 27 1 Select Cleaning Time with buttons 27 2 Press the OK button 27 3 Select Turn Off Time with buttons 1 255 min 27 4 Confirm with OK button 27 5 Press the button The parameter change i...

Page 26: ...with OK button 28 5 Press the button The tap is deactivated for the pre set time The sensor LED flashes green every 10 s Only the selected action is executed The Cleaning Time function can be ended ah...

Page 27: ...s the OK button 29 3 Select Turn Off Time with buttons 1 255s 29 4 Confirm with OK button 29 5 Press the button The parameter change is sent to the tap 30 Switching off the tap The tap can be permanen...

Page 28: ...operating voltage has been applied see instructions for the taps Select the following menu items to go to the destination display 31 1 Select Basin Filling with buttons 31 2 Press the OK button 31 3...

Page 29: ...e destination display 32 1 Select Basin Filling Time with buttons 32 2 Press the OK button 32 3 Set the Basin Filling Time with buttons 0 255s 32 4 Confirm with OK button 32 5 Press the button The par...

Page 30: ...3 4 Confirm with OK button 33 5 Press the button The water flows for the pre set time Only the selected action is executed The Basin Filling function can be ended ahead of time 33 6 Select Basin Filli...

Page 31: ...Select the following menu items to go to the destination display 34 1 Select DetectionFeedback with buttons 34 2 Press the OK button 34 3 Set DetectionFeedback to ON with buttons 34 4 Confirm with OK...

Page 32: ...lights up green the tap is not triggered Select the following menu items to go to the destination display 35 1 Select Body Approach with buttons 35 2 Press the OK button 35 3 Set Body Approach to ON w...

Page 33: ...s to go to the destination display 36 1 Select Hygiene Purge with buttons 36 2 Press the OK button 36 3 Set Hygiene Purge to ON or OFF with buttons 36 4 Confirm with OK button 36 5 Press the button Th...

Page 34: ...last Hygiene Purge Select the following menu items to go to the destination display 37 1 Select Hygiene Interval with buttons 37 2 Press the OK button 37 3 Select Hygiene Interval with buttons 0 255s...

Page 35: ...estination display 38 1 Select Hygiene Flow Time with buttons 38 2 Press the OK button 38 3 Select Hygiene Flow Time with buttons 0 255s 38 4 Confirm with OK button 38 5 Press the button The parameter...

Page 36: ...tons 39 4 Confirm with OK button 39 5 Press the button Hygiene Flush starts Only the selected action is executed Hygiene Flush can be ended ahead of time 39 6 Select Hygiene Flush with buttons 39 7 Pr...

Page 37: ...hen are the extraction points flushed in turn with the outlet open The thermal disinfection must be carried out section by section depending on the size of the installation and the pipe run The indivi...

Page 38: ...tion display 41 1 Select TD Delay Time with buttons 41 2 Press the OK button 41 3 Set TD Delay Time with buttons 0 255 s 41 4 Confirm with OK button 41 5 Press the button The parameter change is sent...

Page 39: ...the destination display 42 1 Select TD Impact Time with buttons 42 2 Press the OK button 42 3 Set TD Impact Time with buttons 0 255 min 42 4 Confirm with OK button 42 5 button The parameter change is...

Page 40: ...on display 43 1 Select TD Cooling Time with buttons 43 2 Press the OK button 43 3 Set TD Cooling Time with buttons 0 255 min 43 4 Confirm with OK button 43 5 Press the button The parameter change is s...

Page 41: ...items to go to the destination display 44 1 Select TD Safety Period with buttons 44 2 Press the OK button 44 3 Set TD Safety Period with buttons 0 255 min 44 4 Confirm with OK button 44 5 Press the b...

Page 42: ...estination display 45 1 Select TD Water Saving F with buttons 45 2 Press the OK button 45 3 Set TD Water Saving F to ON or OFF with buttons 45 4 Confirm with OK button 45 5 Press the button The parame...

Page 43: ...TD to START with buttons 46 4 Press the button The tap flashes orange at 2 second intervals during the entire thermal disinfection Only the selected action is executed Thermal Disinfection can be end...

Page 44: ...Hot water flows 10 s after start of the thermal disinfection at the earliest Impact time Hot water flows for 2 min After 2 min the water flows intermittently for the rest of the pre set time applicati...

Page 45: ...after 31 days Select the following menu items to go to the destination display 47 1 Select Statistics with buttons 47 2 Press the OK button 47 3 Set Statistics to ON with buttons 47 4 Confirm with OK...

Page 46: ...imum of 10 days with retrospective effect N A is indicated in the case of more than 10 days TD done indicates whether the last thermal disinfection was carried out without interruption Last Hyg indica...

Page 47: ...on display 49 1 Navigate downwards with the buttons to display the desired statistics file 49 2 Select the statistics file with the OK button to display the desired statistical data 14 Jan 2018 16 03...

Page 48: ...data is displayed 50 1 Navigate downwards with the buttons 50 2 Mark Save Statistics 50 3 Confirm with OK button The statistical data is stored A csv file is generated Important The statistical data c...

Page 49: ...49 ZMI_001_2030036654 ACEX9005_ SEN_ AQU_V1 fm Notes...

Page 50: ...ZMI_001_2030036654 ACEX9005_ SEN_ AQU_V1 fm 50 Notes...

Page 51: ...51 ZMI_001_2030036654 ACEX9005_ SEN_ AQU_V1 fm Notes...

Page 52: ...21 426 9670 South Africa Sub Saharan Africa Franke South Africa Durban 4052 Phone 27 31 450 6300 Spain Franke GmbH 6971 Hard Austria Phone 43 5574 6735 211 Switzerland Liechtenstein Franke Water Syste...

Reviews: