background image

7

EN

We recommend that the connection of a gas garden heater to liquefied gas cylinders, as well 

as its adjustment and checking the tightness of the installation to be made by an authorized 

gas equipment installer or authorized service technician in accordance with applicable regu-

lations, which should be confirmed on the product warranty card. Lack of such confirmation 

voids the warranty!

DEVICE INSTALLATION AND STORAGE OF BOTTLES SHOULD BE IN COMPLIANCE WITH APPLI-

CABLE LAWS

NEVER USE ANY PARTS OF THE APPLIANCE NOT PROVIDED OR RECOMMENDED BY THE MA-

NUFACTURER!

NOTES ABOUT HANDLING:

This device is designed for easy installation and movement. Before moving it, make sure that all 

anti-removal components have been uninstalled, the gas supply has been cut off, and the hose 

is disconnected from the heater gas cylinder. Moving the device while it is in operation is strictly 

prohibited. After placing the heater in the desired place, secure it against slipping, falling out or 

falling over.

WARNING: DO NOT MOVE THE APPLIANCE WHEN IT IS IN OPERATION!

WARNING!

The OUTDOORFIRE gas garden heater is adapted to work with a cylinder or a household tank of a 

propane-butane gas mixture. The flexible connection pipe should be intended for LPG from the 

cylinder.

The device is sold with complete automation and tubes connecting the main burner and pilot 

burner with the valve. Do not use replacement system components other than those installed or 

supplied by the manufacturer or recommended by your dealer or manufacturer.

FOR OUTDOORFIRE W and OUTDOORFIRE B WITH GV32 MANUAL CONTROL:

• A complete, ready-to-use burner with a full gas control control system armed with the MERTIK MA

-

XITROL GV32 controller.

• A set of decorative stones for a burner.

• Installation and operating instructions.

• Steel body with wheels and stabilizing feet.

• 0.6 m hose with regulator and anti-tilt safety valve

INSTALLATION - INTRODUCTION

The device has an open combustion chamber without the option of connecting it to a chimney flue. 

The OUTDOORFIRE gas garden heater is sold with the pre-installed gas control control system, howe-

ver, before the first use it is recommended to check the tightness of the system due to the possibility 

of its unsealing in transport. All instructions on how to properly connect the system, installation in the 

table and frame can be found below in the following instructions.

All European type GAS cylinders up to 11 kg weight and not wider than 33 cm or higher than 65 

cm are compatible with the appliance.

INSTALLATION RULES

Installation should be carried out in accordance with the requirements of the law in force in the given 

country or region. In the absence of such provisions, the rules contained in this manual and the princi-

ples of fire safety should be followed.

This appliance has been tested for quality and safety and has been certified by a notified testing la-

boratory.

Summary of Contents for OUTDOORFIRE B

Page 1: ...GAS OUTDOOR HEATER OUTDOORFIRE W OUTDOORFIRE B User Manual and Warranty Card EN...

Page 2: ...S OF THIS MANUAL Read the whole manual and share it with every possible user of the device before using the device Any modifications to this device are strictly forbidden Never attempt to tamper with...

Page 3: ...3 EN APPLIANCE DIMENSIONS Fig 1 Dimensional drawing of the OUTDOORFIRE W OUTDOORFIRE B heater...

Page 4: ...ry I3P 30 I3P 37 I3P 50 I3B P 30 I3B P 37 I3B P 50 I3 30 37 Destination countries FI NL RO BE CH CZ ES FR GB GR HR IE IT LT NL PL PT SI SK AT CH DE NL SK BE CY DK EE FR GB GR HU HR IT LT NL NO RO SE S...

Page 5: ...s for any damage It is very important that the gas control system remains intact and free from any damage The device can be serviced only by a qualified technician with appropriate qualifications Fail...

Page 6: ...osed to accidental contact with the apppliance If necessary use safety barriers to limit access to the applinace NEVER obstruct THE VENTILATION ROOM OF A GAS CYLINDER Under no circumstances any of sol...

Page 7: ...pilot burner with the valve Do not use replacement system components other than those installed or supplied by the manufacturer or recommended by your dealer or manufacturer FOR OUTDOORFIRE W and OUT...

Page 8: ...as well as hot elements of the burner Check the correctness and tightness of the installed gas control control system and the entire gas system of the device To do this you can use soapy water or a d...

Page 9: ...brakes for easy movement and safe positioning of the device To move the appliance unlock the brakes on the wheels and move the appliance The other way to move the appliance is to slightly lift the ma...

Page 10: ...precipitation STORING A GAS GARDEN HEATER OUTSIDE THE BUILDING IS ONLY PERMITTED WHEN COVE RING THE RAIN COVER IN ANY OTHER ACCIDENT THE DEVICE SHOULD BE LOCATED IN A PLACE WHICH PROTECTED AGAINST FL...

Page 11: ...pace from flammable materials objects The space indicated above is the minimum free space from flammable materials unless this is removed by another entry Failure to observe the above clearances free...

Page 12: ...FOR USE OUTDOORS OR IN AMPLY VENTILATED ARE AN AMPLY VENTILATED AREA MUST HAVE A MINIMUM OF 25 OF THE SURFACE AREA OPEN THE SURFACE AREA IS THE SUM OF THE WALLS SURFACE ARRANGEMENT OF DECORATIVE STONE...

Page 13: ...ve elements were not installed before the first installation then to remove them the side walls and glass of the device should be removed as shown below DECORATIVE GLASS WALLS OPTION There are two ver...

Page 14: ...ime needed to cool down the hottest elements of the device is about 60 minutes Do not touch the glass or the upper casing parts within an hour after switching off the device Step 1 Remove the screws t...

Page 15: ...15 EN Step 3 Tilt the side walls slightly towards you and then lifting them up remove them from the mounting holes Step 4 Loosen the screws of the window clamps and remove the windows...

Page 16: ...places designated for this Moving them may expose the device to damage due to harmful temperatures or flooding The appliance can only work with the gas control valve supplied with the appliance Connec...

Page 17: ...17 EN Gas pressure reducer Shut off tilt valve Igniter Thermocouple Interrupter block Burner GV32 controller Control pills Fig 8 Connection diagram for the GV32 manual gas control system...

Page 18: ...block Fig 9 Connection diagram for the GV60 automatic gas control system Magneto wire Receiver Igniter Sterownik GV60 GV32 controller Steuerer GV32 GV32 Controlador GV60 Control burner Shut off tilt...

Page 19: ...r damaged or if one of them is missing the device cannot be used until the seals are replaced The valve must remain in the position it is installed at the factory Changing the angle of the valve with...

Page 20: ...to the gas source only when the heater is turned off and the cylinder valve is turned off Never connect the gas cylinder directly to the appliance without the regulator Before replacing the cylinder m...

Page 21: ...any way Firing up the device 1 Turn the ON OFF Knob A knob slightly counterclockwise towards the IGNITION position until it stops Then press the knob for 5 seconds the gas will only flow to the contr...

Page 22: ...er OFF shutting off The operating know is in OFF position The thermo electric flame failure device is close position 1 Ignition The operating knob is in PILOT position The magnet unit is open allowing...

Page 23: ...uld be carried out on a cooled down device with the gas supply cut off and the power supply disconnected ATTENTION Maintenance of the heater must only be performed by a qualified service technician Th...

Page 24: ...leaning Check that all air inlets to the combustion chamber are clear If necessary clear the holes Check the combustion chamber for signs of corrosion If necessary remove corrosion and cover the defec...

Page 25: ...FRAM GmbH Industriestra e 12 22 49324 Melle www fram gmbh de...

Reviews: