Construction Hoist Fraco SEH Premium Range
Assembly and Operating Manual
Page 36 of 69
doc no. 98030718-01
7.8 Bottom
limit switch cam
Fig.
27
Bottom
limit
switch
bar
Make sure that the limit switches shut off the circuit. For more informa-
tion see section 7.9.
7.9 Safeguarding
the
loading and unloading points
Fall protection that will prevent a person falling must be fitted at
all
loading and unloading
points where there is a risk of falling from a height of more than 10’0” (3 m) (confirm with local
regulation). Use approved general-purpose safety belt
when working outside the car.
Only landing gates which guarantee safe transfer to the building in combination with a plat-
form are permitted for the tested and approved Fraco hoists.
A limit switch cam (2) must be mounted
as lowest stop point before the car
drives in to the bottom buffer. A minimal
distance of 51" (1295
mm) must be
maintained from the end of the cam to
the base landing.
Working from the car, attach the limit
switch cam (2) to the mast section and
fasten it in place.
The car is stopped at this bar by the
down operating limit switch or the emer-
gency limit switch if there is a fault.