Construction Hoist Fraco SEH Premium Range
Assembly and Operating Manual
Page 33 of 69
doc no. 98030718-01
ATTENTION
Make sure that the distance according to picture does not exceed 9.5 in (240 mm).
Remember to attach the top limit cam after mounting the last mast sec-
tion!
7.5 Cable Guide system
1 = Junction box
2 = Cable support with guide
3 = Cable guide
4 = Cable guide trolley
Cable support must be installed to secure the cable.
The more acute the wind force at the location of the
machine, the shorter the distances between the cable
guides must be.
Max. distance: 15ft (4,5 m)
.
Attach the cable support with guide under the
junction box
Attach cable support at regular interval all along
the mast.
For more information see the "installation instruction
manual"
Fig. 25 Cable guide system
1
2
3
4