FPI P36D Zero Clearance Direct Vent Gas Fireplace
36
INSTALLATION
5) Position Log 02-53 across the cutouts in
Logs 02-75 and 02-51 with the notch on the
left side of the log fitting into the 2nd grate
tab.
Cutouts
2nd Grate Tab
02-53
02-75
02-51
02-51
02-53
Notch
Bracket
Bracket
02-51
02-75
02-51
4) Place Log 02-51 on the front right side of
the burner. Push the back of the log against
the 2 brackets with the notch on the bottom
right side of the log fitting into the right side
of the grate.
LOG SET
INSTALLATION
Read the instructions below carefully and
refer to the diagrams. If logs are broken
do not use the unit until they are replaced.
Broken logs can interfere with the pilot
operation.
The gas log kit (Part # 780-930) contains the
following pieces:
a) 02-75
Rear Log
b) 02-55
Middle Left Log
c ) 02-50
Front Left Log
d) 02-53
Center Left Log
e) 02-51
Front Bottom Log
f )
02-54
Center Right Log
g) 02-52
Middle Right Log
h)
Embers
NOTE: If you will be installing the optional
Brick Panels, install the Brick Pan-
els prior to installing the logs.
1) Carefully remove the logs from the box and
unwrap them. The logs are fragile, handle
with care - do not force into position.
3) Place the Log 02-75 on the rear log support
pins with the flat side to the back.
The "02" refer numbers (i.e. 02-75) are
molded into the rear of each log.
OPTIONAL
BRICK PANELS
1) Undo the bottom 2 door latches and open
and remove glass door. Remove logs.
Note: The logs must not be in the unit.
2) Insert the back brick panel first by carefully
slipping it between the back wall of the
firebox and the rear log bracket.
3) Put the side panels in next. Slide them in
from the front and push them flat up against
the wall. Be very careful not to scratch
them on the firebox hardware.
4) Install the 2 brick retaining clips, one on
each side.
02-75
Note: If the bottom brick panel must be re-
moved: Remove the Rear Log Stand, then
remove the Burner Tray.
.
02-75
02-55
02-52
02-50
02-53
02-51
02-54
Notch
6) Position Log 02-54 across the cutouts in
Logs 02-51 and 02-53. The notch in the
bottom right end fitting against the 5th grate
tab.
2) Sprinkle the vermiculite all over the top of the
base brick panel.
Summary of Contents for P36D-LP
Page 6: ...FPI P36D Zero Clearance Direct Vent Gas Fireplace 6 UNIT DIMENSIONS...
Page 46: ...FPI P36D Zero Clearance Direct Vent Gas Fireplace 46 FLUSH BAY DOOR OPTIONS...
Page 53: ...FPI P36D Zero Clearance Direct Vent Gas Fireplace 53 CAST FACEPLATE...
Page 62: ...FPI P36D Zero Clearance Direct Vent Gas Fireplace 62 REPLACEMENT PARTS LIST...