FPI P36D Zero Clearance Direct Vent Gas Fireplace
11
Because of the extreme heat this fireplace emits, the mantel clearances are
critical.
Combustible mantel clearances from top of unit are shown in Diagrams 1, 2, & 3.
REGENCY COMBUSTIBLE MANTEL CLEARANCES
These drawings are to scale at 1:6 (one inch = 6 inches)
Mantel can be installed anywhere in shaded area or higher using the above scale.
Note:
Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour.
Note:
A non-combustible mantel may be installed at a lower height if the
framing is made of metal studs covered with a non-combustible board.
Diagram 1
Diagram 2
Diagram 3
INSTALLATION