FPI P36D Zero Clearance Direct Vent Gas Fireplace
27
V1
H1
H
V
INSTALLATION
Horizontal Venting with Two (2) 90
o
Elbows
Option V
H + H1
A)
0' Min. 2' Max.
B)
1' Min. 3' Max.
C)
2' Min. 4' Max.
D)
3' Min. 5' Max.
E)
4' Min. 6' Max.
F)
5' Min. 7' Max.
G)
6' Min.
8' Max.
With these options, maxi-
mum total pipe length is 30
feet with minimum of 6 feet
total vertical and maximum
8 feet total horizontal.
Please note minimum 1
foot between 90
o
elbows
is required.
Horizontal Venting with Three (3) 90
o
Elbows
Option V
H V + V1
H + H1
A)
0' Min.
1' Max.
1' Min.
2' Max.
B)
1' Min.
2' Max.
3' Min.
3' Max.
C)
2' Min.
2' Max.
5' Min.
4' Max.
D)
3' Min.
2' Max.
7' Min.
5' Max.
E)
4' Min.
3 Max.
9' Min.
6' Max.
F)
5' Min.
4' Max.
10' Min. 7' Max.
G)
6' Min.
5' Max.
11' Min. 8' Max.
H)
7' Min.
6' Max.
12' Min. 9' Max.
With these options,
max. total pipe length
is 30 feet with min. of
12 feet total vertical
and max. 9 feet total
horizontal.
Please note min. 1
foot between 90
o
elbows is required.
One 90
o
elbow = Two 45
o
elbows.
One 90
o
elbow = Two 45
o
elbows.
H
H1
V
Lengths do not include elbow indicated.
Lengths do not include elbow indicated.
Summary of Contents for P36D-LP
Page 6: ...FPI P36D Zero Clearance Direct Vent Gas Fireplace 6 UNIT DIMENSIONS...
Page 46: ...FPI P36D Zero Clearance Direct Vent Gas Fireplace 46 FLUSH BAY DOOR OPTIONS...
Page 53: ...FPI P36D Zero Clearance Direct Vent Gas Fireplace 53 CAST FACEPLATE...
Page 62: ...FPI P36D Zero Clearance Direct Vent Gas Fireplace 62 REPLACEMENT PARTS LIST...