IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
EQUIPMENT RELATED, INSTALLATION AND GENERAL USE
Installation of all GALAXY 2000 models
When installing and using the GALAXY 2000 unit, basic safety precautions must always be
followed, including the following:
1.
Follow all aspects of the local and National Electrical Code(s) when installing the GALAXY
2000 unit.
2. During installation, mount the GALAXY 2000 unit to ensure the least amount of direct
exposure to rain, garden sprinkler water, direct sunlight or any corrosive environment.
3. WARNING - Risk of electrical shock. Install at least 1.5 m (5 feet) from the inside wall of the
pool or spa using non-metallic plumbing.
4. WARNING - Do not use spas, hot tubs or pools unless all suction grates are installed to pre-
vent body and hair entrapment.
5. DANGER - To reduce the risk of drowning from hair and body entrapment, install suction fit -
ting(s) with a marked flow rate that equals or exceeds the flow rate on the equipment
assembly.
6. WARNING - Install blower no less than 30 cm (1 foot) above the maximum water level to pre -
vent water from contacting electrical equipment.
7. Do not install the GALAXY 2000 unit within an outer enclosure or beneath the skirt of a hot
tub or spa.
8. CAUTION - Maintain water chemistry in accordance with manufacturer's instructions.
9. All field -installed metal components such as rails, ladders, drains, or other similar hardware
within 3 m (10 feet) of the spa or hot tub shall be bonded to the equipment grounding bus
with copper conductors not smaller than No. 8 AWG in the U.S.A. and No. 6 AWG in Canada.