NT500 VAG Scanner User’s Guide_English Version_V1.00
44
Figure 4-76 Sample Recalibration Operation Screen
7.
Press the function key
OK
to continue and when the recalibration completed, the following
screen displays.
Figure 4-77 Sample Recalibration Done Screen
8.
Press function key
OK
to finish the test or use
Back
key to return to the function menu.
5 OBDII/EOBD Operations
OBD-II/EOBD menu lets you access all OBD service modes. According to ISO 9141-2, ISO
14230-4, and SAE J1850 standards, the OBD application is divided into several sub programs,
called ‘Service $xx’. Below is a list of OBD diagnostic services:
●
Service $01
- request current powertrain diagnostic data
●
Service $02
- request powertrain freeze frame data
●
Service $03
- request emission-related diagnostic trouble codes
●
Service $04
- clear/reset emission-related diagnostic information
●
Service $05
- request oxygen sensor monitoring test results
●
Service $06
- request on-board monitoring test results for specific monitored systems
●
Service $07
- request emission-related diagnostic trouble codes detected during current or
last completed driving cycle
●
Service $08
- request control of on-board system, test or component
●
Service $09
- request Vehicle Information
When OBDII/EOBD application is selected from Home screen, the scanner starts to detect the
communicaiton protocol autometically. Once the connection has established, a menu that lists all
of the tests available on the identified vehicle displays. Menu options typically include:
●
System Status
●
Read Codes
●
Freeze Frame Data
●
Erase Codes