NT500 VAG Scanner User’s Guide_English Version_V1.00
32
Figure 4-45 Sample Basic Setting on Most Control Mudules Screen
NOTE
The function key is only available on Engine Controllers that are OBD-II compliant (all 1996 and
newer US-Model) or EOBD compliant (all 2001 and newer European-market models). Non-US
models and older TDIs may not support the Readiness function even though they are otherwise
OBD-II compliant. OBD-I did not require any "monitors".
4.
However, there are no longer any channel or group numbers for the latest control modules
using UDS/ODX/ASAM protocols. Instead, the Basic Setting to be performed must be selected.
So for the control modules using UDS/ODX/ASAM, the following screens shows.
Figure 4-46 Sample Basic Setting Selection Screen
5.
Select an option and press the function key
Start
to activate the test.
Figure 4-47 Sample Basic Setting Screen
6.
In controllers using KWP-2000/CAN/UDS, there may be an ON/OFF button that allows you to
initiate and exit Basic Settings while still being able to see the values in the measuring channel.
However, this does not appear every time and its appearance and function are up to each
controller in the car.
7.
Use the
BACK
key to exit.
●
You should refer to the Service Manual for your particular car before attempting to use the Basic
Settings function. Failure to follow the proper procedures can result in serious damage to the
vehicle.
●
Although you can use the
Next
and
Previous
function keys to scroll through the available
channels, this is probably not a good idea since you may put the controller into Basic Settings
for a Channel that you did not intend.
4.1.3.11 Adaptation
Adaptation menu let you change adaptation values from the control module and allows you to