Part of ft heevice
Cleaning
Housing
Use a microfiber cloth to remove light and
stubborn dirt.
Modeling bulb, flash
tube
Wipe off with dust brush or dry, soft cloth
ADVICE:
Don´t clean the modeling bulb and flash tube
with water. Even small residues on the bulbs
could lead to bursting
Reflector
Remove dirt with microfiber cloth
17.3.
Change flash tube
WARNING
Please just use flash tubes, which are conform with the required
specifications as to avoid the bursting of the flash tube. See
Technical
Specifications
.
WARNING
Posterior danger of bursting of flash tube
Don´t touch the flash tube with bare hands. Wear clean cotton gloves or
use a clean cloth.
A
Flash Tube
B
Retention Clip
C
Socket for modeling lamp
1.
Discharge device:
WARNING!
Danger of electric shock. Discharge the device before
changing the flash tube.
•
Switch on device.
See
Switch the device on and off
.
•
Trigger flash:
Press push-button TEST and switch off main switch immediately.
ADVICE: If you don´t switch off the main switch within 0,5 seconds, the
device will charge anew.
•
Unplug power cord.
2.
Let the device cool down.
WARNING!
Danger of burning on reflector, modeling lamp and flash
tube. Please let the device cool down for approx. 30 minutes.
3.
Remove old flash tube:
•
Demount reflector.
See
Demount and mount reflector.
•
Screw out modeling lamp.
See
Screw in and out of modeling lamp
.
•
Hook off the retention clip with pliers.
•
Hold the flash tube at the right and left side of the socket.
CAUTION!
Danger of cutting and splitting through breaking flash
tube. Just touch the flash tube in the range of the plug-in contact and
not at the levitated flash ring.
•
Agitate the flash tube carefully and pull it out from the socket.
4.
Attach new flash tube:
•
Place the two plug-in contacts of the flash tube loose into the socket.
•
Press the flash tube with even, slight pressure on the plug-in contacts
into the socket as far as it goes.
CAUTION!
Danger of cutting and splitting through breaking flash
tube. Put the pressure only on the range above the plug-in contacts
and not on the levitated ring flash.
B
A
C
27
28