6.
Put the device and all demounted elements into the original styrofoam
box and carry and store them according to ft heequirements in the
technical specifications. See
Technical specifications
.
16.
Solve problems
Problem
Possible reason
Remedy
Flash device is switched
on, but has no function
Power cord is not
plugged or plugged
incorrect
Plug in the power cord
correctly
Micro-fuse is defect
Change micro-fuse, see
Change micro-fuse
Flash device has
function, but flash
trigger is not possible
Flash capacitor is
defect
Contact our service
department
Modeling lamp flickers
Modeling lamp is
defect
Change modeling lamp,
see
Screw in and out
modeling bulb
The following notice is shown in the display
Problem with
operation
temperature
Switch off the device
immediately. Contact the
Foto Walser service
department
Problem with power
output
Switch off the device for
approx. 30 minutes.
Danger of overloading
Internal voltage
inside the flash is too
high
Switch on/off the flash. If
you still have the defect,
contact the Foto Walser
service department
17.
Maintenance
17.1.
Continuous inspections
What you should do?
Before every
operation
If necessary
Check all cables and plugs for damages.
In case of damage:
WARNING!
Danger of electric shock
and fire through short-circuit
The device should be repaired by an
electrician immediately.
X
Charge flash capacitor
See
Charge of flash capacitor
X
17.2.
Cleaning
WARNING
Posterior danger of bursting of flash tube
Make sure not to touch the flash tube with bare hands accidentally.
WARNING
Danger of electric shock
Just use the specified cleaning supplies.
The contact with moisture or water should be avoided.
Disconnect from power supply during cleaning.
25