WIRING
INTERNAL WIRING DIAGRAM
CH heaters are equipped with two Hi-temperature
silicone lead wires and a bonding* (ground)
termination.
ELECTRICAL SHOCK
HAZARD
•
Serious injury or death
may occur.
•
Disconnect from electrical
supply before installing or
servicing this heater.
•
Read and follow all safety
information in box below.
Make certain the power source
conforms to specifications on the
heater label.
Do not depend on a thermostat or
other switch as the sole means of
disconnecting power when installing
or servicing heater. Always unplug
the cordset or open the safety switch
and lock it open.
All wiring must be performed by a
licensed electrician.
The cordsets supplied with these
heaters are equipped with provisions
for proper bonding (grounding).
Always mate the cordset plug with the
proper bonded (grounded) receptacle
in accordance with the National
Electric Code and all governing local
codes and ordinances.
Do not use an extension cord to
provide power to these heaters.
Never connect the green or green-
yellow wire to a live or “hot”
conductor.
Hi-temp. wires
Cordset
Quartz Lamp
*Bonding is the term that describes the completion of
the electrical circuit back to its source, which allows a
breaker or fuse to clear if a short occurs in the line.
Heater Housing