QUARTZ TUBE INSTALLATION
ELECTRICAL SHOCK
HAZARD
•
Serious injury or death
may occur.
•
Disconnect from electrical
supply before installing or
servicing this heater.
•
Reflector end caps must be
installed prior to powering
the unit; refer to note #3.
HEATER INSTALLATION
Install heater so that the quartz tubes are
horizontal. Failure to do this may cause the
heating element within the tube to sag and cause
premature burnout.
FIRE HAZARD
•
Serious injury or death may
occur.
•
Read and follow clearances
shown in box at left for ALL
CH series heater installations.
•
Do not use inside residences.
MINIMUM INSTALLATION CLEARANCES
These heaters MUST be installed as follows:
CH-46C:
o
12 inches min. from a vertical surface.
CH-57C:
o
24 inches min. from a vertical surface.
72 inches minimum from ANY combustible
material
3 inches minimum from the ceiling
36 inches minimum from other heaters
NOTE: For optimum spot heating performance, it is recommended that the distance from the floor should be
approximately 7 to 9 feet for CH-46 models, and 8 to 10 feet for CH-57 models.
QUARTZ TUBE
LOCK WASHER
HEX NUT
RING TERMINAL
Each heater is equipped with two hi-temperature silicone lead
wires and a ground termination.
Make sure power source
conforms to the heater requirements. Use only Fostoria
quartz tubes.
1. Insert quartz tube in the “L”-shaped slots in heater housing.
2. On each end of the quartz tube, place (1) lead wire ring
terminal, (1) lock washer and (1) hex nut on the threaded
stud and
tighten securely
(see image below). Lock washers
and hex nuts are provided in hardware package.
NOTE – Use a second wrench to hold the inner hex nut in
place while tightening the outer hex nut.
Failure to
securely tighten this connection will cause the element
to fail prematurely.
3. Attach reflector end caps to both ends of housing using the
(4) screws provided in hardware package.