Issue Date: 09-25-07 Rev. Date: 04-24-08 Rev. Level: 03 ECN: n/a OIPM P/N: 3420203
Page 4 of 8
QUARTZ TUBE INSTALLATION
ELECTRICAL SHOCK
HAZARD
•
Serious injury or death
may occur.
•
Disconnect from electrical
supply before installing or
servicing this heater.
•
Reflector end caps must be
installed prior to powering
the unit; refer to note #3.
HEATER INSTALLATION
Install heater so that the quartz tubes are
horizontal. Failure to do this may cause the
heating element within the tube to sag and cause
premature burnout.
FIRE HAZARD
•
Serious injury or death may
occur.
•
Read and follow clearances
shown in box at left for ALL
OCH series heater
installations.
•
Do not use inside residences.
MINIMUM INSTALLATION CLEARANCES
These heaters MUST be installed as follows:
12 inches minimum from a vertical surface
72 inches minimum from ANY combustible
material
3 inches minimum from the ceiling
36 inches minimum from other heaters
NOTE: For optimum spot heating performance, it is recommended that the distance from the floor
should be approximately 7 to 9 feet for OCH-46 models, and 8 to 10 feet for OCH-57 models.
Each heater is equipped with two black hi-temperature silicone lead
wires and one green lead wire for ground termination.
Make sure
power source conforms to the heater requirements. Use only
Fostoria quartz tubes.
1.
Insert quartz tube in the “L”-shaped slots in heater
housing.
2.
On each end of the quartz tube, place (1) lead wire ring
terminal, (1) lock washer and (1) hex nut on the threaded stud
and
tighten securely
(see image below). Lock washers and
hex nuts are provided in hardware package.
One lead wire is already installed in your heater, the
second lead wire is located in the hardware package.
NOTE – Use a second wrench to hold the inner hex nut in place
while tightening the outer hex nut. Failure to securely tighten this
connection will cause the element to fail prematurely.
3.
Attach reflector end caps to both ends of housing using
the (4) screws provided in hardware package.
QUARTZ TUBE
LOCK WASHER
HEX NUT
RING TERMINAL