To start the Self Check mode, press the EXECUTE/YES
key when “?” is blinking.
As shown in the left, “SelfCheck”, “CurrentDr”, name of
connected SCSI drive (The example on the left shows that
the Magneto Optical drive MOS350 is connected to the FD-
8 SCSI port.) and “ATA Bus C (check)” appear on the FD-
8 LCD display in order.
If a 2.5" internal E-IDE hard disk drive is not installed in
the FD-8, the Self Check mode comes to a standstill at “ATA
Bus C (check)” test.
In order to continue the Self Check mode, press the
EXECUTE/YES key again.
4-5. Self Check
This mode automatically tests the following points in order.
• SCSI bus
• ATA (E-IDE) bus
• MIDI in/out circuit
• S/P DIF digital signal (44.1kHz)
• Vari-pitch circuit
• A/D and D/A circuit (Input Monitor)
<Cable Connection in “Self Check” Mode>
Continue to next page
In order not to form a MIDI signal loop,
connect the MIDI cable after putting the FD-
8 into the Service Mode.
CAUTION:
: blinking