EN
HOW THE COOKER
HOOD WORKS
A:
Light ON/OFF key
The light switches on and off only when the carria-
ge is fully OPEN.
Pressing this button with the carriage closed will
cause the carriage to open and then the light will
switch on.
The button also serves to switch off the light if it
is on.
B:
ON/OFF key
This starts the extraction carriage upward move-
ment and when it is fully open, it sets the second
extraction speed.
With the carriage open: it switches off the motor
and if on, the light; then it retracts the extraction
carriage.
C:
Key
This reduces the speed of the extractor motor from
the 4
th
speed until the motor switches off, wi-
thout closing the pull-out carriage.
D:
Indicators
• This signals the speed setting, by only the
relevant LED switching on.
• This signals that all filters have been saturated
by all LEDs switching on.
E:
Key
This increases the speed of the extractor motor,
from 1st to 4th speed, without moving the extractor
panel.
F:
Timer
10 min after setting, it serves to stop the extractor
motor, close the carriage and switch the lights off,
if they are on. The set function is signalled by the
flashing LEDs “D” for the set speed. The timer can
be cancelled by pressing the key again.
Other functions:
Automatic turn off:
After 4 hours of continuous working from the last
setup, the appliance turns off and closes automa-
tically.
Grease filters saturation:
After 30 hours of working, the speed indicators
“D”
will all flash simultaneously, signaling the gre-
ase filters saturation.
To reset this alarm, hold down the
“TIMER”
button
for at least 3 seconds, while the carriage is open.
Calibration:
The cooker-hood carries out its self-calibration
every 3 complete cycles of its extractable unit.
By pushing the
“TIMER”
key 6 times consecuti-
vely (MAX break between one push and the other
is 3 sec.) all the leds will flash and the calibration
will be reset.
After the next 3 cycles the downdraft will carry out
its self-calibration.
Stand-by:
When the extractable unit is closed and the light
is switched off, the control panel, after 6 secon-
ds, activates the Stand-by function, reducing the
brightness of the leds.
This function can be stopped by pressing
ON/OFF
or
LIGHT
key.
MODEL SDD2-L GLASS VERSION
16
SU-DD2
Summary of Contents for GHOST 2451 946
Page 2: ......
Page 3: ...IMAGES 3 SU DD2...
Page 4: ...Fig 1 Fig 6 Fig 2 Fig 3 Fig 4 Fig 5 4 SU DD2...
Page 5: ...5 SU DD2 Fig 7 Fig 11 Fig 8 Fig 9 Fig 10 Fig 12...
Page 6: ...Fig 13 6 SU DD2...
Page 11: ...DESCRIPTION OF THE APPLIANCE EN INC 11 SU DD2...
Page 22: ...EN 22 SU DD2...
Page 23: ...EN 23 SU DD2...
Page 24: ...90002022564 02 19...