background image

EN

OPERATIONAL

ANOMALIES

PROBLEM

SOLUTION

The cooker hood

does not work...

The cooker hood has

low performances...

The cooker hood

stops in the middle of

operation.

Check that:

● There is not a power outage.

● A specific speed has actually been selected.

● The 9 pole connection is inserted properly.

● The red reset key, found over the electrical system box, is pushed.

● Make sure that the wires of the 9 pole connection are inserted properly

  in the connector itself (during the connection phase, an excessive

  pressure could bend the contacts).

Check that:

● The motor speed selected is sufficient for the quantity of fumes and

vapors present in the room.

● The kitchen is ventilated well enough to allow air for intake.

● The charcoal filter is not worn out.( filtering version cooker hood).

● The air outlet channel is free and compliant with paragraph no. 2.

● The non-return valves of the suctioning unit are free to rotate.

Check that:

● There is not a power outage.

● The omnipolar device has not tripped.

AFTER SALES SERVICE

Any maintenance operation on your appliance should be carried out by:

● Either your retailer;

● Or another qualified professional technician, authorized for that brand.

When calling, please mention the appliance details (Type Fig. 13A and equipment Fig. 13B and 

production date Fig. 13C).

This information is mentioned on the rating label and the production date one placed on the lower 

side of the downdraft.

NOTA

19

SU-DD2

Summary of Contents for GHOST 2451 946

Page 1: ...S DD2 L FLUSH TOP GHOST 2451 946 BEFORE INSTALLATION ENSURE THERE IS NO VISIBLE OR HIDDEN DAMAGE SUSTAINED DURING SHIPPING SHIPPING DAMAGE MUST BE REPORTED WITHIN 5 DAYS OF RECEIPT...

Page 2: ......

Page 3: ...IMAGES 3 SU DD2...

Page 4: ...Fig 1 Fig 6 Fig 2 Fig 3 Fig 4 Fig 5 4 SU DD2...

Page 5: ...5 SU DD2 Fig 7 Fig 11 Fig 8 Fig 9 Fig 10 Fig 12...

Page 6: ...Fig 13 6 SU DD2...

Page 7: ...HE HOOD 12 Grease filter removal mounting the activated charcoal filter 14 Electrical connection of the hood 15 HOW THE COOKER HOOD WORKS 16 CLEANING THE COOKER HOOD 18 OPERATIONALANOMALIES 19 AFTER S...

Page 8: ...encing installation All electrical wiring must be properly installed insulated and grounded and conform to all applicable codes and standards Make sure all existing duct work is clean of grease build...

Page 9: ...with external motor fornormal downdraft operation it is necessary to use a suctioning unit external motor made by the same manufacturer The air collected must not be conveyed into a flue used for smo...

Page 10: ...with external motor fornormal downdraft operation it is necessary to use a suctioning unit external motor made by the same manufacturer The air collected must not be conveyed into a flue used for smo...

Page 11: ...DESCRIPTION OF THE APPLIANCE EN INC 11 SU DD2...

Page 12: ...oes not exceed 5 meters Limit the number of elbows in the piping since each elbow reduces the air capacity of 1 linear meter Ex if you use no 2 x 90 el bows the length of piping should not exceed 3 me...

Page 13: ...aft Select an air outlet from the five possibilities Fig 9 and fit the union supplied with the appliance Place the metal box with the electronic com ponents in an easily reachable area for even tual t...

Page 14: ...to a duct conveying the air on one side of the cabinet Fig 11 CAUTION Installation must comply with the regulations in force regarding the ventilation of enclosed environments In particular discharged...

Page 15: ...ower is enough Feeder lines mains are in good conditions The cables diameter complies with installation regulations Place the metal box containing the electronic components at a distance of no less th...

Page 16: ...r motor close the carriage and switch the lights off if they are on The set function is signalled by the flashing LEDs D for the set speed The timer can be cancelled by pressing the key again Other fu...

Page 17: ...has to be carried out by a specialized technician WARNING Security system If there is an obstacle while the extractable unit is closing the Downdraft stops closing and rises again thanks to a security...

Page 18: ...o clean the external surfaces of the cookerhood and the light housing screen use only commercially avai lable household detergents diluted in water Then rinse with clean water and dry with a soft clot...

Page 19: ...and vapors present in the room The kitchen is ventilated well enough to allow air for intake The charcoal filter is not worn out filtering version cooker hood The air outlet channel is free and compl...

Page 20: ...ervene directly during use and or maintenance and which may be subject to wear The formation of rust and stains on the steel due to the use of unsuitable cleaning agents Any functional defect indicate...

Page 21: ...time by FOSTER with the desire of offering the best service available FOSTER is not liable for any damages direct or indirect caused to people objects and pets for failure to follow all the instructi...

Page 22: ...EN 22 SU DD2...

Page 23: ...EN 23 SU DD2...

Page 24: ...90002022564 02 19...

Reviews: