Forza FDC-003K User Manual Download Page 4

1-5. Maintenance, service and faults

2. OPERATION
2-1. Unpacking and inspection

2-2. UPS front and rear panel views
UPS front view picture





One UPS unit
One user manual
One monitoring software CD (ForzaTracker)
One USB cable
Warranty certificate

Carefully inspect the UPS to check for any damages that may have occurred during shipping. Should any evidence of 
damage be found or if some parts are missing, do not turn the UPS on; you must immediately notify the carrier or dealer 
where you purchased the unit.

Remove the UPS from its package and make sure that all the following items are included:





The voltage used by this UPS may be hazardous. The unit contains no user serviceable parts; do not attempt to 
disassemble the unit. Only qualified service technicians can perform maintenance on the unit. Failure to adhere to this 
could cause personal injury or equipment malfunction and void the warranty. 

Caution

 - risk of electric shock. Even after the unit is disconnected from the mains, components inside the UPS system 

are still connected to the battery packs which are potentially dangerous. 
Before carrying out any kind of service and/or maintenance, disconnect the batteries and verify that no current is 
present and no hazardous voltage exists in the terminals of high capacity capacitors, such as BUS-capacitors. Servicing 
of batteries should be performed or supervised by experts who possess the knowledge to closely follow all required 
precautions. 

Caution

: potentially hazardous voltages from the battery can still be present even after disconnecting the UPS from the 

AC mains. Therefore, the positive and negative terminals of the battery shall de disconnected prior to performing any 
maintenance or repair inside the unit. 
A battery can present the risk of short-circuit current and electrical shock. The following precautions should be taken:
- remove wristwatches, rings and other metal objects
- use only tools with insulated grips and handles. 
When replacing the battery, make sure to use the same type and number of sealed lead-acid batteries specified. 
Do not dispose of batteries in a fire. Batteries may explode if exposed to high temperatures.
Never try to open a battery. The cell contains a toxic electrolyte which is harmful to the skin and eyes.
Please replace the fuse only with the same type and amperage in order to avoid fire hazards. 
Do not dismantle the UPS system.

Summary of Contents for FDC-003K

Page 1: ...2 Y e a r W a r r a n t y...

Page 2: ...Important Safety Instructions 1 5 Maintenance Service and Faults 2 1 Unpacking and inspection 2 2 UPS front and rear panel views 2 3 Installation Procedure 2 4 Forza Tracker monitoring software 3 1 De...

Page 3: ...s Do not connect appliances or equipment that may overload the UPS system such as a laser printer to the output sockets Place cables in such a way that no one can step on or trip over them Do not conn...

Page 4: ...efore carrying out any kind of service and or maintenance disconnect the batteries and verify that no current is present and no hazardous voltage exists in the terminals of high capacity capacitors su...

Page 5: ...ical devices to the general outlets During power failure you may extend the backup time to critical devices by setting shorter backup time for non critical devices For terminal type input or outputs p...

Page 6: ...es safe auto shutdown for multi computer systems during power failures With this software users can monitor and control any UPS on the same LAN no matter how far they might be from the UPS To allow fo...

Page 7: ...errors occur Up key Press this button to display previous selection in the UPS configuration menu Switch to UPS self test mode Press and hold ON Mute button for 5 seconds to perform the self test in...

Page 8: ...3 2 LCD panel...

Page 9: ...r at 0 25 26 50 51 75 and 76 100 of its capacity Overload indicator Indicates the load or the UPS output is short circuited Indicates that programmable management outlets are working Indicates the UPS...

Page 10: ...ues of each program 3 3 Audible alarm 3 4 Abbreviations on the LCD display 3 5 UPS parameter settings Battery mode Low battery Overload Fault Bypass mode Beeps once every 4 seconds Beeps once every se...

Page 11: ...110 The output voltage is 110VAC 115 The output voltage is 115VAC 120 The output voltage is 120VAC 127 The output voltage is 127VAC Interface Setting Parameter 2 3 Activates or cancels the converter...

Page 12: ...inal voltage For 100 110 115 120 127 VAC the setting in parameter 3 ranges from 3V to 12V of the nominal voltage Interface Setting Parameter 3 Use it to activate or cancel the Bypass mode ENA Bypass e...

Page 13: ...ts for the programmable outlets 0 999 Use this setting to define the programmable outlets backup time in minutes from 0 999 in order to connect non critical devices on battery mode Interface Setting P...

Page 14: ...ode When the input voltage exceeds the acceptable range or during a power failure the UPS will start supplying power from the battery while the alarm will beep every 4 seconds When input is within acc...

Page 15: ...Beeps once every second Beeps once every second Beeps once every second Beeps once every second Over temperature Charger failure Out of bypass voltage range Beeps once every second Beeps twice every s...

Page 16: ...incorrect Battery voltage is too low or the charger fails UPS is overloaded UPS is overloaded Devices connected to the UPS are fed directly from utility power via the Bypass After repetitive overloads...

Page 17: ...condition in the output Defective batteries Batteries are not fully charged Charge the batteries for at least 5 hours and then check their capacity If the problem persists consult your dealer Contact...

Page 18: ...n immediately in battery mode or transfer to bypass mode when utility power is normal Output voltage AC voltage regulation Frequency range synchronized range Frequency range batt mode Current crest ra...