6. Specifications

Voltage range

Overload

Transfer time

AC mode

to batt. mode

Inverter to bypass

AC mode

Battery mode

Dimensions (mm)
Net weight (kg)

Tower case

Humidity
Noise level

Smart RS-232 or USB

Optional SNMP

20-90 % RH @ 0- 40°C (non-condensing)

Less than 45dBA @ 1 meter

Supports Windows® 2000/2003/XP/Vista/2008/7,

Linux, Unix and MAC

Power management from SNMP manager

and web browser

Battery type
Quantity
Recharge time
Charging current
Charging voltage

12 V / 9 Ah

6

4 hours to 90% capacity (typical)

1.0 A (max.)

82.1 VDC ±1%

421 X 190 X 318

28

Frequency range
Phase
Power factor

Single phase with ground

 0.99 @ 220-230 VAC (input voltage)

100%~110%: audible warning

110%-130%: UPS shuts down in 30 seconds in battery mode

or transfers to bypass mode when utility power is normal.

>130%: UPS shuts down immediately in battery mode

or transfer to bypass mode when utility power is normal

Output voltage
AC voltage regulation
Frequency range (synchronized range)
Frequency range (batt. mode)

Current crest ratio

3:1

~ 85%

~ 83%

~ 88%

Harmonic distortion

≤3 % THD (linear load)

≤6 % THD (non-linear load)

≤ 4 % THD (linear load) 

≤ 7 % THD (non-linear load)

200/208/220/230/240VAC or 100/110/115/120/127 VAC

± 3% (batt. mode)

47 ~ 53 Hz or 57 ~ 63 Hz

50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz

Low line transfer

Low line comeback
High line transfer
High line comeback

3000 VA / 2400 W

300 VAC ± 5 % or 150 VAC ± 5 %
290 VAC ± 5 % or 145 VAC ± 5 %

40Hz ~ 70 Hz

Zero

Waveform (batt. mode)

Pure sine wave

4 ms (typical)

High line transfer voltage - 10V

160VAC / 140VAC / 120VAC / 110VAC ± 5 % or

80VAC / 70VAC / 60VAC / 50VAC ± 5 %

(based on load percentage

100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)

Model

CAPACITY*
INPUT

OUTPUT

EFFICIENCY

BATTERY

PHYSICAL

ENVIRONMENT

MANAGEMENT

FDC-003K

* Derate capacity to 60% of capacity in Frequency converter mode and to 80% when the output voltage 
  is adjusted to 208VAC.

Summary of Contents for FDC-003K

Page 1: ...2 Y e a r W a r r a n t y...

Page 2: ...Important Safety Instructions 1 5 Maintenance Service and Faults 2 1 Unpacking and inspection 2 2 UPS front and rear panel views 2 3 Installation Procedure 2 4 Forza Tracker monitoring software 3 1 De...

Page 3: ...s Do not connect appliances or equipment that may overload the UPS system such as a laser printer to the output sockets Place cables in such a way that no one can step on or trip over them Do not conn...

Page 4: ...efore carrying out any kind of service and or maintenance disconnect the batteries and verify that no current is present and no hazardous voltage exists in the terminals of high capacity capacitors su...

Page 5: ...ical devices to the general outlets During power failure you may extend the backup time to critical devices by setting shorter backup time for non critical devices For terminal type input or outputs p...

Page 6: ...es safe auto shutdown for multi computer systems during power failures With this software users can monitor and control any UPS on the same LAN no matter how far they might be from the UPS To allow fo...

Page 7: ...errors occur Up key Press this button to display previous selection in the UPS configuration menu Switch to UPS self test mode Press and hold ON Mute button for 5 seconds to perform the self test in...

Page 8: ...3 2 LCD panel...

Page 9: ...r at 0 25 26 50 51 75 and 76 100 of its capacity Overload indicator Indicates the load or the UPS output is short circuited Indicates that programmable management outlets are working Indicates the UPS...

Page 10: ...ues of each program 3 3 Audible alarm 3 4 Abbreviations on the LCD display 3 5 UPS parameter settings Battery mode Low battery Overload Fault Bypass mode Beeps once every 4 seconds Beeps once every se...

Page 11: ...110 The output voltage is 110VAC 115 The output voltage is 115VAC 120 The output voltage is 120VAC 127 The output voltage is 127VAC Interface Setting Parameter 2 3 Activates or cancels the converter...

Page 12: ...inal voltage For 100 110 115 120 127 VAC the setting in parameter 3 ranges from 3V to 12V of the nominal voltage Interface Setting Parameter 3 Use it to activate or cancel the Bypass mode ENA Bypass e...

Page 13: ...ts for the programmable outlets 0 999 Use this setting to define the programmable outlets backup time in minutes from 0 999 in order to connect non critical devices on battery mode Interface Setting P...

Page 14: ...ode When the input voltage exceeds the acceptable range or during a power failure the UPS will start supplying power from the battery while the alarm will beep every 4 seconds When input is within acc...

Page 15: ...Beeps once every second Beeps once every second Beeps once every second Beeps once every second Over temperature Charger failure Out of bypass voltage range Beeps once every second Beeps twice every s...

Page 16: ...incorrect Battery voltage is too low or the charger fails UPS is overloaded UPS is overloaded Devices connected to the UPS are fed directly from utility power via the Bypass After repetitive overloads...

Page 17: ...condition in the output Defective batteries Batteries are not fully charged Charge the batteries for at least 5 hours and then check their capacity If the problem persists consult your dealer Contact...

Page 18: ...n immediately in battery mode or transfer to bypass mode when utility power is normal Output voltage AC voltage regulation Frequency range synchronized range Frequency range batt mode Current crest ra...

Reviews: