1. Introduction

Thank you for purchasing the Forza Atlas 3000 Online UPS. To enjoy all the features and benefits of this unit, please read 
and follow all installation and operation instructions thoroughly before unpacking, installing or operating this device. After 
you have read this manual, keep it in a safe place for future reference.
The information contained in this manual covers the 3000 VA uninterruptible power system, its basic functions, operating 
procedures, options available and troubleshooting guide. It also includes information on how to ship, store, handle, and 
install the equipment.

1-1. Transportation

   Make sure to transport the UPS system only in the original package to protect it against shock and impact.

1-2. Preliminary steps

  Water condensation may occur if the UPS is unpacked in a very cold environment and then moved to a warmer location. 
  The UPS must be thoroughly dry before being installed. Failure to do so may increase the risk of electric shock. 
  Do not install the UPS system near water or in moist environments. 
  Do not install the UPS system where it would be exposed to direct sunlight or near a heater or heating vent. 
  Do not block ventilation holes in the UPS housing.

1-3. Initial setup

1-4. Important safety instructions










Do not connect appliances or equipment that may overload the UPS system (such as a laser printer) to the output 
sockets. 
Place cables in such a way that no one can step on or trip over them. 
Do not connect domestic appliances, such as hair dryers, to the UPS output sockets. 
Connect the UPS system only to an earthed shockproof outlet which must be easily accessible and close to the UPS 
system. 
Use CE-marked cables for connections between mains, the UPS and equipment (shockproof outlet). 
Use CE-marked power cables to connect the loads to the UPS system. 
During the installation of this equipment, make sure that the sum of the leakage currents of the UPS and the connected 
loads shall not exceed 3.5 mA.

Do not disconnect the mains cable on the UPS system or the building wiring outlet (shockproof socket outlet) at any time, 
since this would cancel the protective earth of the UPS system and of all connected loads. 
Connect the UPS only to a grounded socket that meets electrical safety guidelines. 
Locate the UPS near a wall socket. Do not use an extension cord between the UPS and the socket. 
In the event of an emergency, press the OFF/Enter button and disconnect the power cord from the AC mains to properly 
disable the UPS. Do not allow any kind of liquid or foreign object to enter this UPS unit. 
Do not place beverages or any other containers with liquid on or nearby the unit.
The UPS can be operated by any individuals with no previous experience.

Summary of Contents for FDC-003K

Page 1: ...2 Y e a r W a r r a n t y...

Page 2: ...Important Safety Instructions 1 5 Maintenance Service and Faults 2 1 Unpacking and inspection 2 2 UPS front and rear panel views 2 3 Installation Procedure 2 4 Forza Tracker monitoring software 3 1 De...

Page 3: ...s Do not connect appliances or equipment that may overload the UPS system such as a laser printer to the output sockets Place cables in such a way that no one can step on or trip over them Do not conn...

Page 4: ...efore carrying out any kind of service and or maintenance disconnect the batteries and verify that no current is present and no hazardous voltage exists in the terminals of high capacity capacitors su...

Page 5: ...ical devices to the general outlets During power failure you may extend the backup time to critical devices by setting shorter backup time for non critical devices For terminal type input or outputs p...

Page 6: ...es safe auto shutdown for multi computer systems during power failures With this software users can monitor and control any UPS on the same LAN no matter how far they might be from the UPS To allow fo...

Page 7: ...errors occur Up key Press this button to display previous selection in the UPS configuration menu Switch to UPS self test mode Press and hold ON Mute button for 5 seconds to perform the self test in...

Page 8: ...3 2 LCD panel...

Page 9: ...r at 0 25 26 50 51 75 and 76 100 of its capacity Overload indicator Indicates the load or the UPS output is short circuited Indicates that programmable management outlets are working Indicates the UPS...

Page 10: ...ues of each program 3 3 Audible alarm 3 4 Abbreviations on the LCD display 3 5 UPS parameter settings Battery mode Low battery Overload Fault Bypass mode Beeps once every 4 seconds Beeps once every se...

Page 11: ...110 The output voltage is 110VAC 115 The output voltage is 115VAC 120 The output voltage is 120VAC 127 The output voltage is 127VAC Interface Setting Parameter 2 3 Activates or cancels the converter...

Page 12: ...inal voltage For 100 110 115 120 127 VAC the setting in parameter 3 ranges from 3V to 12V of the nominal voltage Interface Setting Parameter 3 Use it to activate or cancel the Bypass mode ENA Bypass e...

Page 13: ...ts for the programmable outlets 0 999 Use this setting to define the programmable outlets backup time in minutes from 0 999 in order to connect non critical devices on battery mode Interface Setting P...

Page 14: ...ode When the input voltage exceeds the acceptable range or during a power failure the UPS will start supplying power from the battery while the alarm will beep every 4 seconds When input is within acc...

Page 15: ...Beeps once every second Beeps once every second Beeps once every second Beeps once every second Over temperature Charger failure Out of bypass voltage range Beeps once every second Beeps twice every s...

Page 16: ...incorrect Battery voltage is too low or the charger fails UPS is overloaded UPS is overloaded Devices connected to the UPS are fed directly from utility power via the Bypass After repetitive overloads...

Page 17: ...condition in the output Defective batteries Batteries are not fully charged Charge the batteries for at least 5 hours and then check their capacity If the problem persists consult your dealer Contact...

Page 18: ...n immediately in battery mode or transfer to bypass mode when utility power is normal Output voltage AC voltage regulation Frequency range synchronized range Frequency range batt mode Current crest ra...

Reviews: