9.10 During deploying or when after all sectors of the boundary are deployed it is necessary to mark
sectors numbers on the draft.
Sector number corresponds to the number of the mark or pointer of Tx
of this sector.
9.11 When the operator comes to the guard station, it is necessary to check the status of all deployed
sectors. Check that there are not alarms (see item 5.1.8) and AC reports (see item 5.1.10).
9.12 If there are AC reports from one or several sectors testify that signals do not pass over a radio
channel. In this case try to find in the room of guard station the place of RC Rx installation according to
item 8.5.3. If it is impossible, install the remote antenna according to procedure given in item 8.5.
Disconnect a spike antenna and connect a remote antenna to RC Rx “
АНТЕННА
” (ANTENNA) plug-
and-socket. After that check the setting of all deployed sectors to “Automatic Control” mode.
Note.
1
If AC reports are not reset, then after a remote antenna is connected, sectors (including those
which generate AC reports) are set to “Automatic Control” mode automatically. If AC reports are reset,
these sectors are set to “Automatic Control” mode again, because when AC reports are reset, the sector
automatic control is OFF.
2
A remote antenna is recommended to install at that place where the distance between a
protective boundary and the guard station is over 200m and if a guard station is inside reinforced
concrete buildings.
10 SYSTEM OPERATION
10.1
Operation Procedure
10.1.1
The system operates in automatic mode within SB continuous operation time mode specified
in item 3.12.
10.1.2
Control the system operability periodically (at least once a day) using check passes along
each of deployed sectors.
10.1.3
The system is dislocated in arbitrary order. Rx and Tx power supply is OFF automatically
when they are removed from the poles. Set “
ПИТАНИЕ
” switch (“POWER SUPPLY” switch) to “0”
position to switch off RC Rx power supply. Pack the system components into bags and rucksacks
according to the instructions given in item “Complete Set” 4372-43071246-007
ПС
.
10.1.4
After the system is dislocated, charge SB of all Rxs, Txs and RC Rxs of the system including
those which did not operate. Record the date of SB charge in item “Special Notes” 4373-43071246-007
ПС
.
ATTENTION! Storage of charged SB decreases their service life.
10.2
SB Charge Procedure
10.2.1
Shift two catches 15 (see fig.6.4) to the centre and remove the charger front cover.
10.2.2
Check the integrity and accuracy of a mains cord and mains plug visually. Earth a charger
using a bonding point. Connect a mains plug to 220V mains socket. Switch on a charger by setting
“
СЕТЬ
” switch (“MAINS” switch) to “1” position. 8 LEDs “
НОРМА
” (“NORM” LEDs) must be ON.