20
10.2.3
Connect a cable of any channel of the charger to the plug-and-socket on its storage battery
compartment to charge a Tx (Rx) storage battery. Simultaneously connect two channels of a charger to
two plug-and-sockets “
ЗАРЯД
БАТАРЕИ
” (“BATTERY CHARGE”) of RC Rx to charge a RC Rx
storage battery.
If after the units is connected, “
ЗАРЯД
” LED (“CHARGE” LED) is ON, then the unit storage
battery is discharged and its charge is less than 85% of rated capacity. In this case the charge time is
equal to the period of time from the moment of connection to the moment when “
ЗАРЯД
” LED
becomes dim of this channel and plus 2-3 hours.
If “
ЗАРЯД
” LED (“CHARGE” LED) of this channel is not ON while connecting the unit, the
minimum charge time of this storage battery must be 2 hours.
Notes
1
It is possible to enlarge the charge time, it does not cause SB overcharge.
2 The charge time of discharged SB to the moment when “
ЗАРЯД
” LED becomes dim is 9 hours
maximum (given as a reference).
3 Intensity of “
НОРМА
” LED (“NORM” LED) glowing can decrease after SB is connected. This
decrease is defined by the SB discharge degree.
10.2.4
When charging is over, disconnect charger cables from the units and insert cable sockets into
the corresponding clamps. Set “
СЕТЬ
” switch to “0”. Disconnect a mains plug from the mains and insert
it into the special socket on the false panel.
10.2.5
Place the front cover, put cables under it, fix the cover with the catches shifting them to the
centre.
IT IS PROHIBITTED
to go on SB charging if after its connection “
НОРМА
” LED is OFF and it is
not ON after 10 minutes of charging.
IT IS PROHIBITTED
to keep batteries connected to charger channels after the charger is OFF
because the batteries discharge via the charger input circuits.
11 MAINTENANCE
11.1
General Instructions
11.1.1
The system is maintained according to the schedule-prevention system which provides the
following interval of routine maintenance:
-
maintenance after use;
-
semi-annual maintenance.
11.1.2
The system maintenance is carried out by the consumer’s technicians.
11.2
Maintenance Procedure
11.2.1
Maintenance after use includes:
-
check of external view of the system components
-
SB charging of the system units.