Using the Module
39
CMx-BTx
4
Using the Module
4.1
SEMA functions
The onboard micro controller provides SEMA (Smart Embedded Management Agent) function-
ality, which monitors and gathers hardware status and performance information from the system
through the SMBus (System Management Bus). The following list highlights the SEMA functions
available on the CMx-BTx.
Total operating hours counter
Counts the time the module has been run in minutes
On-time minutes counter
Counts the seconds since last system start
Temperature monitoring of the board
Stores minimum and maximum temperatures in the flash of the micro controller
Automatic shut down on over temperature events
Power monitor
Reads the current drawn by the module and reports the nominal operating voltage
Power cycles counter
Boot counter
Increases Boot count after a HW- or SW- Reset or after a successful power up
Watchdog Timer
Sets | Resets | Disables Watchdog Timer
System restart cause
Identifies Power loss | Watchdog event | External reset
Flash area
Provides 1 kByte Flash for customer data
Protected Flash area
Provides 128 Bytes Flash for Keys, IDs, etc. stored in a write- and clear-protectable
region
Board Identify
Identifies Vendor | Board | Serial number
The SEMA tools are available for Windows, Linux, and VxWorks. SEMA functionality can also
be used in applications. Refer to the SEMA software manual and technical manual on the
ADLINK web site for more information.
Summary of Contents for CM1-BT1
Page 5: ...iv...
Page 9: ...viii...
Page 15: ...6 Introduction...
Page 23: ...14 Getting Started BLANK PAGE...
Page 57: ...48 Using the Module 4 4 10 Main System Management Smart Fan 4 4 11 Advanced...
Page 76: ...Using the Module 67 CMx BTx 4 4 48 Security 4 4 49 Boot...
Page 77: ...68 Using the Module 4 4 50 Boot CSM Configuration 4 4 51 Boot Delete Boot Option...