13
2. Check the air shutter adjustment – sharp blue flame, with no yellow tipping or lifting flames.
3. Check ignition of oven burner.
4. Visually check tubular burner (oven burner) re-ignition to be sure both rows of burner ports are relighting each
time.
5. Check for gas leaks at all gas connections (using a gas detector, never a flame).
6. Check oven bake and convection bake function.
Gas Conversion Operation
This cooking range can be used with LP gas and NG gas. It is shipped from the factory adjusted for use with
NG(Nature Gas). Injector for LP gas are included. Follow the instruction shown below for gas conversion.
WARNING
Gas conversion shall be conducted by a factory- trained professional. Call the
customer service hotline to identify a factory-trained professional near your home.
WARNING
Before carrying out this operation, disconnect the range from gas and electricity.
Fail to do so, may result in fire, or electrical shock hazard can occur and result in
injury or death. Do not remove regulator or allow it to turn during servicing.
The gas conversion procedure for this range includes 8 steps:
1. Pressure regulator
5. Air shutter for oven burner (optional)
2. Surface burners
6. Gas valves
3. Oven burner
7. Reconnect Gas and Electrical Supply
4. Broil burner
8. Installation of new rating label
The conversion is not completed if all 8 steps have not been concluded properly.
Before performing the gas conversion, locate the package containing the replacement injectors shipped with every
range.
STEP 1:
Pressure Regulator
The gas regulator is located at the bottom right corner inside the oven. Operate 3 steps to access the gas
regulator.
Counter top