Table 5.
Parameter
Maximum power (kW)
3
Voltage / frequency
(V/Hz)
400/50 - 60
Fuse (A)
3x20
3x30
4.2.3 Technical data- hydraulic system
4.2.3.1 Technical data- hydraulic appratus
Table 6.
Parameter
Motor power (kW)
2.2
47.2 mm²
Voltage / frequency
(V/Hz)
3x400/50
2x220/60
Control of executive elements (VDC)
24
Tank capacity (l)
12
4.2.3.2 Technical data- oil for hydraulics
Table 7.
Parameter
Oil type
HV 46
Quality
ISO 11158 - HV
Viscosity
ISO VG 46
Norm DIN
51524, 46 mm2
(cST).
Kinematic viscosity in temperature (
40°C)
The hydraulic system does not require de-aeration, it takes place automatically after
several cuts.