Table 9.
Position
LED diode color
Indication
Text
1
yellow
Work status
indicator
PWR
2
red
Error indication
ERR
5.3 Electrical apparatus
The cutter is supplied with a five-core copper wire with 2.5 mm2 wire cross-
section. The user's duty is to install the cutter to the electrical network with 20 A
safeguards. For connecting, use a copper wire with a cross-sectional area of 2.5
mm2 or more. Voltage fluctuations should be in the range of 90-110% of the
rated voltage, and fre
quency fluctuations in the range of 50 Hz ± 2%.
The cutter can be connected to a five-core, L1, L2, L3, N, PE electric network.
Danger!
Dangerous electrical voltage!
Before opening the housing, switch off the main switch!
1. Hinged housing of electrical apparatus (Fig. 13)
2. Nuts fixing the housing (Fig. 13)
Figure 13. Location of electrical apparatus