Battery Part Numbers and Usage
Size
Quantity
Type
Battery Part Number
Single Battery 2.2 FWD (without Start-Stop)
T7
1
700 CCA (80Ah @20 hour rate)
6C16-10655-C_*
Twin Battery 2.2 FWD (without Start-Stop)
T7
2
700 CCA (80Ah @ 20 hour rate)
6C16-10655-C_*
Twin Battery (with Start-Stop)***
T7
2
700 CCA (75Ah @ 20 hour rate)
CC1T-10655-B_**
High Performance Deep Cycle AGM Batteries ***
H7
2
800 CCA (80Ah @ 20 hour rate)
CC1V-10655-A_
*Can be replaced by BV6N-10655-P_ in service.
**Can be replaced by 8G9N-10655-B_ in service.
***Compatible with SRC and Start-Stop vehicles only.
Battery Rules:
•
Batteries in parallel must be of the same type
and capacity when using the SureStart ®
system and listed in the Ford battery table.
•
Third party batteries are isolated from the
standard Ford system at key off.
•
For External charging of batteries ensure that
the maximum voltage of 15.2V is not exceeded.
Normal proprietary charging equipment should
operate below this voltage.
NOTE:
Charge balance calculations are required
when adding additional systems taking into
account alternator size and battery capacity. On
battery choice a number of factors are important:
•
Battery specification capability in ampere hours
for continuously loading until empty. For
instance an 80Ah fully charged battery can
supply 4 Ampere over a 20 hour period at 20
degrees centigrade until it is fully discharged.
•
The Cold Crank Ampere (CCA) rating is the
maximum rating for cold start requirements.
•
For deep cycling and micro cycling requirements
(engine off loads) the deep cycle battery
system (A736) is recommended
Always observe circuit set-up outlined in diagram
E74522 - Battery Disconnect Relay (Split Charge
Relay) Circuit, later in this section. Extra batteries
added to the power supply should be connected
as shown at the end of this section.
4.4.2 Battery Configurations
Battery Configurations (always in the drivers
seat pedestal)
Battery Configuration
Description
Item
Vehicle Start Battery
1
Auxiliary Battery
2
Single standard battery system — Without Start-Stop
A
Twin standard battery system — Standard Duty — Without Start-Stop
B
Improved flooded standard order battery — Start-Stop (K)
C
Twin special vehicle option battery system — With and without Start-Stop (J)
D
Arrow = Front of vehicle direction
FORD
TRANSIT CUSTOM
2012.75
Date of Publication: 04/2012
4 El
ec
tric
al
82