8
USE AND CLEANING
INFORMATION
3
Control descriptions
-
Temperature indicator light (A)
-
Adjustment thermostat 0°- 90°C (B)
-
Loaded circuit breaker (C) with voltage led
-
Power cord inlet (D) + cord
-
Limit thermostat (E), not found in mod. CL2760-70/C
Recommendations for use
Before using the machine remove, if found, the special protective film.
Unpleasant odours produced during the first minutes of operation are due to the presence of processing
grease residues.
On first use, heat the machine to the maximum temperature.
Lunch counter and thermal trolley use
Pour water (possibly decalcified) in the basin until a level of approximately 3 cm is reached (approximately 5
lt. for models
BM1780-CT1756-CS1751
, 10 lt. for models
BM1782-CT1758-CS1753-CL2760C
, 14 lt. for
models
BM1784-CT1760-CS1755-CL2770C
). The water level must be periodically restored, to avoid serious
equipment damage. The equipment must be installed connecting the power cords to the proper sockets
foreseen in the working environment where they must be placed. To turn the machine on, press the main
switch -it will light up- and turn the thermostat knob to set the required temperature (al least 65°C); the red
led will light up indicating that the resistance is working correctly. Once the required temperature has been
reached, the led will turn off and it will turn back on when the temperature decreases enough (approximately
5° C) to justify resistance functions.
All machines, except models
CL2760C-CL2770C,
are equipped with a limit thermostat that starts working
when high temperatures are reached to protect the equipment. The resistance must cool down before the
machine is re-started pressing the proper button.
At the end of the day, turn the main switch off, leaving the temperature set.
End of the day cleaning
•
Remove the plug from the electrical socket at the end of the day.
•
Accurately clean using neutral products.
•
Clean external machine parts with a damp sponge when the machine is fully cooled.
•
Do not use metallic pads and abrasive detergents.
•
To avoid hazards caused by contact with high temperature parts, only access heating parts after
maintenance operations have been completed.
Extended periods of disuse
For extended periods of disuse, turn off the main wall switch, clean the machine and cover it with a cloth to
protect if from dust.