71
Storing Salvo Data on a Remote Control Unit (MFR-39RU/39RUA only)
Use a
SALVO
button on the remote control unit as shown in the procedure below.
1.
Assign a
SALVO
button on the remote control unit. Set the salvo for
RU STORE
.
► See Sec. 5-4-3-2. “BTN ASSIGN.”
2.
Store salvo data as shown in the table below.
Step
Description
1
Press the
SALVO
button.
The button is highlighted and ready for
crosspoints to be assigned.
2
To assign crosspoints to a salvo, press
a destination button then a source button.
The selected buttons flash.
Repeat the procedure for all crosspoints.
3
MFR-39RU:
After completing the crosspoint assignments, repress the
SALVO
button.
The menu display appears as shown below.
MFR-39RUA:
After completing the crosspoints assignments, repress the
SALVO
button.
The Current DEST and SRC button displays change as shown below.
4
MFR-39RU:
To add crosspoints to an existing salvo, select a salvo number by turning
CONTROL
. Salvo numbers to which no crosspoints are assigned are indicated as
NEW. Turn and press the
CONTROL
knob to confirm a number selection.
MFR-39RUA:
Turn, then press the
CONTROL
knob to confirm a number selection.
Executing Salvos
Use a
SALVO
button on the remote control unit as shown in the procedure below.
1.
Assign a
SALVO
button on the remote control unit. Set the salvo for
RU RECALL
, and
select a Salvo number.
► See Sec. 5-4-3-2. “BTN ASSIGN” and 5-5-2. "Changing Button Assignment."
2.
Press the
SALVO
button to execute the salvo. The crosspoints stored to the salvo
number are simultaneously switched.
SALVO STORE
NO: 1 (NEW) <ENT>