10-7. GPI Output Circuit (Same for GPI 1-3)
IMPORTANT
Note that the allowed current for each GPI output circuit is
50 mA
and the external
power supply should be
5-24 VDC
.
+5.0V
Select external or internal
power.
PIN 1, 7, 19
PINs 2-6, 14-18 (OUT)
PIN 13
5-24 V DC
(external power)
Protective resistor
FA-1010 inside