22
5-3-5. Direct Mode Settings
Click
Direct Mode Settings
in the left pane to display the Direct Mode Settings page. This
page allows you to assign Main Units to
MU1
to
MU20
, which are used for direct mode
connections.
Up to 20 MU units (MU 1
– MU 20) can be registered in the Direct Mode list, but they must be
registered in the Unit ID list. (See the previous page).
See section 6-1-2.
“Connecting a Main Unit in Direct Mode” for details on the connection
procedure.
As factory default,
Unit ID 1 to 20
are set to
MU 1 to 20
. If you need to change these
assignments, follow the procedure below.
(1) Change the Unit ID numbers for MU 1 to MU 5. Click the
MU 1
–5
button.
(2) Change the Unit ID numbers for MU 6 to MU 10, then click the
MU 2-10
button. Change
other settings in the same way.
(3) When all settings are finished, click
Apply
.
Note that if another page is entered without clicking
Apply
, the settings are ignored.
IMPORTANT
Note that if an IP address is not set under the associated Unit ID number in the Unit
Assignment page (see section 5-3-4), it cannot be accessed using the Unit ID or MU
number.
When connecting to main units using the 1-5, 6-10, 11-15 or 16-20 button in Direct
mode, user names set in the Unit Assignment page are displayed. If user names are
not set, IP addresses are displayed.
Setting
Unit ID
to “
0
” in the Direct Mode Settings page disables the connection. Use
“0,” as necessary.