25/50 Series 220 V 60 Hz/230 V 50 Hz Dispensers
9
Installing countertop dispensers
1. Position dispenser in desired location, mark dispenser outline on counter and remove dispenser.
2. Drill four 10mm (3/8") holes in counter
(Fig. 2) to anchor dispenser to counter.
Note:
Follett countertop dispensers can have
any or all utilities run directly through counter or
out rear of dispenser. For dispensers with any
utilities exiting through counter, make counter
cut-out (Fig. 2)
3. If ice transport tube will exit out rear of
dispenser, remove ice transport tube knock-out
(Fig. 5G) from rear of dispenser.
Note:
Utility connections can be accessed
through front of dispenser by removing stainless
steel splash panel,
or by removing access panel (Figs. 4, 5)
on back of dispenser.
4. If any electric utilities or water line will be
connected through rear of dispenser, remove
utility knock-out (Figs. 4, 5F) from rear of
dispenser and install supplied protective grommet.
5. If power is to be supplied through counter cut-out, complete steps 6-9. If power is to be supplied through
rear of dispenser, proceed to step 10.
534mm (21")
512mm (20.125")
318mm
420mm
166mm
10mm (.375")
39mm (1.5")
12mm (.44")
267mm
229mm x 356mm
(9" X 14")
DRAIN PAN
cut-out
(10.5")
(12.5")
(16.5")
(6.5")
10mm
holes
(.375")
13mm
(.5")
(G) 10mm (3/8") FPT water inlet
(K) alternate 19mm (3/4") dispenser
drain location
(H) 10mm (3/8") FPT condenser
water inlet
drain pan
(L) 19mm (3/4") FPT dispenser drain
(J) 10mm (3/8") FPT condenser
water outlet
Dispensers with top mount ice machines cannot be mounted on legs. They must be bolted to counter.
Use gloves when lifting ice machine to protect hands from sheet metal edges.
!
Fig. 2 – Counter cut-out, all models
Fig. 3 – Top view, dispenser plumbing connections countertop