25/50 Series 220 V 60 Hz/230 V 50 Hz Dispensers
11
Installing wall mount dispensers
1. Install supplied wall bracket with six 10 mm (3/8") diameter fasteners as shown in Fig. 7.
Note:
Three holes are available at each fastening site to allow capture of studs/support within wall.
Steps 2 - 3 are required for models with integral ice machine only (C/E25HT400A/W and C/E50HT400A/W).
2. For models with integral ice machine, use straight edge to position fi ller strip fl ush with top edge of wall bracket.
3. Fasten fi ller strip to wall as shown in Fig. 8.
4. For all models, cut utility hole in wall (Figs. 7 and 8) using wall bracket as template.
5. Lift dispenser onto wall bracket, positioning unit so that hook on back of dispenser is captured by wall bracket
support angle (Fig. 6, hook detail).
6. Install four 1/4-20 screws through bottom of wall bracket into bottom of dispenser to secure dispenser to bracket.
7. Remove splash panel. Water line to solenoid valve can be disconnected from water inlet valve by pushing on ring at
end of inlet fi tting while pulling on tubing.
111
8
mm (44")
343mm
45
8
mm
5
8
4mm
429mm
305mm (12")
470mm
546mm
64mm
435mm
610mm
(24")
(2.5")
(23")
(16.
8
75")
(1
8
")
(21.5")
(17.125")
(13.5")
(1
8
.5")
C/E25HT400A/W
C/E50HT400A/W
406mm (16")
C/E25HT400A/W
C/E50HT400A/W
1219mm (4
8
")
support angle and
hook detail
Do not rest dispenser weight on bottom front edge of wall bracket.
!
Fig. 6 – Side view and angle detail for wall mount units without drain pan with integral ice machine
(in top of cabinet).
Wall mount units with RIDE ice machines will not require installation of a fi ller strip.