14
Horizon HCD700R/N, HMD700R/N Ice Machines
Electrical system
ATTENTION!
To prevent circuit breaker overload, wait 15 minutes before restarting
this unit.
Normal control board operation
The PC board indicator lights provide all the information necessary to determine the machine's status. Green indicator
lights generally represent “go” or normal operation; Yellow indicators represent normal off conditions; Red indicators
generally represent alarm conditions, some of which will lock the machine off.
A flashing green light labeled POWER indicates power to the machine. All other normal operation status indicators are
covered as follows:
Ice machine disposition
Operating conditions
FLASHING
ON or OFF
Legend:
OFF
ON
1. Ice machine is making ice.
.
1.
Normal running.
2. Ice machine is not making ice.
2.
Normal time delay. When the bin fills with ice, the LOW
BIN light goes out and the refrigeration and auger drive
systems immediately shut down. (
Note: The fan motor
will continue to run for 10 minutes to cool condenser)
The TIME DELAY light comes on, initiating the time delay
period. When the time delay expires, the machine will
restart provided that the LOW BIN light is on.
DIP Switch Settings